2014
DOI: 10.1016/j.phclin.2013.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Essai de stérilité des préparations ophtalmiques sur milieu Reasoner's agar no 2 (R2A) : une solution pour diminuer le temps d’incubation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…Sterility test method was validated (i.e. growth promotion test, validation of the sterility assay and elimination of the inhibitory effect) by Thibert et al (2014) , using a method adapted from the European Pharmacopoeia sterility assay (2.6.1). Multidose eyedroppers were opened under the laminar air flow of an ISO 4.8 microbiological safety cabinet, and the contents filtered under vacuum using a Nalgene analytical test filter funnel onto a 47 mm diameter cellulose nitrate membrane with a pore size of 0.45 μm (ref 147-0045, Thermo Electron SAS; ThermoFisher Scientific, Courtaboeuf Cedex, France).…”
Section: Methodsmentioning
confidence: 99%
“…Sterility test method was validated (i.e. growth promotion test, validation of the sterility assay and elimination of the inhibitory effect) by Thibert et al (2014) , using a method adapted from the European Pharmacopoeia sterility assay (2.6.1). Multidose eyedroppers were opened under the laminar air flow of an ISO 4.8 microbiological safety cabinet, and the contents filtered under vacuum using a Nalgene analytical test filter funnel onto a 47 mm diameter cellulose nitrate membrane with a pore size of 0.45 μm (ref 147-0045, Thermo Electron SAS; ThermoFisher Scientific, Courtaboeuf Cedex, France).…”
Section: Methodsmentioning
confidence: 99%
“…Osmolality was measured for each solution using an osmometer Model 2020 Osmometer® (Advanced instruments Inc, Radiometer, SAS, Neuilly Plaisance).o Sterility assay Sterility test method was validated (i.e. growth promotion test, validation of the sterility assay and elimination of the inhibitory effect) byThibert et al (Thibert et al, 2014), using a method adapted from the European Pharmacopoeia sterility assay (2.6.1). Multidose eyedroppers were opened under the laminar air flow of an ISO 4.8 microbiological safety cabinet, and the contents filtered under vacuum using a Nalgene analytical test filter funnel onto a 47mm diameter cellulose nitrate membrane with a pore size of 0.45µm Thermo Scientific, Thermo Electron SAS, Courtaboeuf Cedex, France).…”
mentioning
confidence: 99%