2018
DOI: 10.1088/1742-6596/1065/8/082013
|View full text |Cite
|
Sign up to set email alerts
|

Establishing traceability for liquid density measurements in Europe: 17RPT02-rhoLiq a new EMPIR joint research project

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…Therefore, this method proofed to be suitable to be use in comparison with a commercial oscillation-type density meter (like the one tested in this work) to determine density of liquids against pressure (i.e. to descibe EOS) and to be used for calibration purposes, as recommended by the standard ASTM D7961 [19], being this one of the subjects to be adressed during the lifetime of the EMPIR Joint Research Project 17RPT02 rhoLiq concerning the establishment of traceability for liquid density measurements [10].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, this method proofed to be suitable to be use in comparison with a commercial oscillation-type density meter (like the one tested in this work) to determine density of liquids against pressure (i.e. to descibe EOS) and to be used for calibration purposes, as recommended by the standard ASTM D7961 [19], being this one of the subjects to be adressed during the lifetime of the EMPIR Joint Research Project 17RPT02 rhoLiq concerning the establishment of traceability for liquid density measurements [10].…”
Section: Discussionmentioning
confidence: 99%
“…This work aimed to provide the basis for the future development of procedures for the calibration of oscillation-type density meters at high-pressures by introducing an alternative calibration methodology to be used as reference, being one of the subjects to be adressed during the lifetime of the EMPIR Joint Research Project 17RPT02 rhoLiq concerning the establishment of traceability for liquid density measurements [10].…”
Section: Introductionmentioning
confidence: 99%
“…Temperature of liquid sample is measured SPRT temperature probe (Hart Scientific) which has measurement uncertainty of 0.01 °C and resolution of 0.0001 °C. For the purpose of obtaining best meniscus on liquid sample surface, Pt-Ir wire used, furthermore before the measurement all apparatus are cleaned with ethanol and in order to reduce evaporation of the liquid sample [14].…”
Section: Methodsmentioning
confidence: 99%
“…Hydrostatic weighing method could be used as reference alternative; however, this method was not yet studied with viscoelastic samples. This corresponds to one of the objectives of the rhoLiq Project [3].…”
Section: Description Of the Workmentioning
confidence: 99%
“…With the purpose of getting the first insight on how different laboratories handle the density measurements' artefacts caused by the viscoelasticity of non-Newtonian fluids when using oscillation-type density meters, an international comparison was performed, within the scope of the EMPIR Project 17RPT02 rhoLiq [3].…”
Section: Introductionmentioning
confidence: 99%