2017
DOI: 10.1016/j.jhazmat.2016.05.079
|View full text |Cite
|
Sign up to set email alerts
|

Estimating population size in wastewater-based epidemiology. Valencia metropolitan area as a case study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
82
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 102 publications
(85 citation statements)
references
References 52 publications
2
82
0
1
Order By: Relevance
“…To ensure that the concentrations of EtS, EtG, Cot, and HCot in the sewer reactors could be measured by direct‐injection LC–MS method, prior to each batch test, the wastewater in the reactors was spiked with a standard mixture of EtS, EtG, Cot, and HCot to increase the biomarker concentrations to approximately 10, 5, 10, and 5 ng/mL, respectively. These initial concentrations were still within the range of concentrations of these compounds measured in the actual wastewater samples from previous studies …”
Section: Methodssupporting
confidence: 86%
See 2 more Smart Citations
“…To ensure that the concentrations of EtS, EtG, Cot, and HCot in the sewer reactors could be measured by direct‐injection LC–MS method, prior to each batch test, the wastewater in the reactors was spiked with a standard mixture of EtS, EtG, Cot, and HCot to increase the biomarker concentrations to approximately 10, 5, 10, and 5 ng/mL, respectively. These initial concentrations were still within the range of concentrations of these compounds measured in the actual wastewater samples from previous studies …”
Section: Methodssupporting
confidence: 86%
“…Due to their popular consumption and high level found in wastewater (high excretion rates), Cot and HCot have been proposed and investigated to be used as population markers . Both studies found Cot and HCot stable in wastewater‐only experiments and concluded that Cot is a suitable population marker.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Regarding creatinine analysis, we developed a quick method that allowed the determination of creatinine in 200 mL of wastewater, achieving a LOQ 0.01 mg/L. Simple dilute and shoot creatinine methods in wastewater have been previously published [42][43][44], showing our method a similar sensitivity and specificity. The concentrations reported in our study, 0.22-2.68 mg/L, were within the range of concentrations previously reported (0.06-10.7 mg/L) [32].…”
Section: Discussionmentioning
confidence: 96%
“…Ezt nemrég egy ausztrál kutatócsoport vizsgá-latai is megerősítették, amelyek során a 2011-es népszámlálás napján vagy környé-kén gyűjtött mintákat elemezték és vetették egybe a cenzusból nyert adatokkal (Gracia-Lor et al [2017], O'Brien et al [2014]). Egy friss valenciai esettanulmányban (Rico-Andrés-Costa-Picó [2017]) pedig a minták koffein-és kotinintartalmának segítségével próbálták finomítani a népességszámra vonatkozó becslést. (A kotinin a nikotin metabolitja.)…”
Section: A Szennyvízelemzés Módszere éS Bizonytalansági Tényezőiunclassified