Estimation of Leaf, Root, and Sap Nitrogen Status using the SPAD‐502 Chlorophyll Meter for Ornamental Shrubs

Abstract: The SPAD-502 chlorophyll meter was evaluated as a rapid tool to predict plant nitrogen (N) concentration. The SPAD-502 index utility, as a comparative tool with respect to N nutritional status, was evaluated for Laurustine (Viburnum tinus L.), tobir (Pittosporum tobira Thumb.), and strawberry tree (Arbutus unedo L.). The effect of sampling time on the SPAD-502 index measures was also evaluated. Two sand culture experiments evaluating 1, 3, 5, and 7 mmol c . L 21 of total N concentration in nutrient solution an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
7
0
2

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 12 publications
0
7
0
2
Order By: Relevance
“…In N-deficient plants, because of low chlorophyll content, the red reflectance is much higher, whereas the infrared region is much lower (Ajay et al, 1984). For some species, correlation between SPAD meter reading and leaf N concentration is low (Martín et al, 2007), and for broad leaf species, multiple measurements per leaf are required to acquire a representative SPAD value for a leaf greatly reducing the speed of acquisition (Chang and Robison, 2003).…”
mentioning
confidence: 99%
“…In N-deficient plants, because of low chlorophyll content, the red reflectance is much higher, whereas the infrared region is much lower (Ajay et al, 1984). For some species, correlation between SPAD meter reading and leaf N concentration is low (Martín et al, 2007), and for broad leaf species, multiple measurements per leaf are required to acquire a representative SPAD value for a leaf greatly reducing the speed of acquisition (Chang and Robison, 2003).…”
mentioning
confidence: 99%
“…The SPAD 502 determines the relative amount of chlorophyll present by measuring the transmittance of the leaf in two wave bands (600-700 and 400-500 nm). It gives a reading in arbitrary unit that is proportional to the amount of chlorophyll present, which could be used to predict crop N requirements (Blackmer and Schepers 1995;Martin et al 2007). Waskom et al (1996) reported that the SPAD 502 worked very well at the rapid growth and tasselling stages of corn.…”
Section: Introductionmentioning
confidence: 99%
“…Schroeder et al (2000) reported that leaf relative chlorophyll content (RCC) measured by the SPAD 502 could not quantify the excess available N during early stages of corn crop compared to the values predicted by soil N content. Martin et al (2007) used the SPAD 502 chlorophyll meter as a rapid tool to evaluate N status in plant leaves, sap, and roots of various ornamental shrub plants and recommend it for field crops. They also indicated that even though the SPAD 502 leaf greenness index was adequate for leaf N and nutritional diagnosis of strawberry plant (Arbutus unedo L.), it was not suited for lauristine (Viburnum tinus L.), taboir (Pittosporum tobira), and thumb (Cotoneaster spp).…”
Section: Introductionmentioning
confidence: 99%
“…(Soil Plant Analysis Development) que determina la concentración de clorofilas de las hojas de una manera no destructiva, mediante diferencias en la transmitancia de la luz emitida por dos diodos a dos longitudes onda, 650 nm (rojo) y 940 nm (infrarrojo) (Monje, Bugbee, 1992;Blackmer, Schepers, 1995;Chang, Robinson, 2003;Martín et al, 2007).…”
Section: Minolta Corporation Desarrolló El Medidor Spad-502unclassified
“…Las unidades SPAD se han relacionado con la concentración de clorofila determinada mediante extracción en numerosos cultivos hortícolas como la lechuga, el tomate, el algodón o el maíz, constatándose en todos ellos, que puede ser una herramienta útil para estimar el contenido en clorofilas de manera no destructiva (Finnan et al, 1997;Rodriguez et al, 1998;Martín et al, 2007;León et al, 2007).…”
Section: Minolta Corporation Desarrolló El Medidor Spad-502unclassified