2012
DOI: 10.1016/j.cmpb.2012.02.003
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of spatial-temporal gait parameters in level walking based on a single accelerometer: Validation on normal subjects by standard gait analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
131
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 163 publications
(141 citation statements)
references
References 27 publications
2
131
0
Order By: Relevance
“…Spatiotemporal parameters of gait were assessed using a validated [10] wireless inertial sensing device (BTS Bioengineering, Italy) attached to the subject's waist using a semi-elastic belt, covering the L4-L5 intervertebral space, to acquire acceleration values for three anatomical axes: the anteroposterior, medial-lateral, and vertical axes. Subjects were asked to walk along an 8-m pathway at a self-selected speed as naturally as possible.…”
Section: Methodsmentioning
confidence: 99%
“…Spatiotemporal parameters of gait were assessed using a validated [10] wireless inertial sensing device (BTS Bioengineering, Italy) attached to the subject's waist using a semi-elastic belt, covering the L4-L5 intervertebral space, to acquire acceleration values for three anatomical axes: the anteroposterior, medial-lateral, and vertical axes. Subjects were asked to walk along an 8-m pathway at a self-selected speed as naturally as possible.…”
Section: Methodsmentioning
confidence: 99%
“…This device is composed of a 16-bit/axis triaxial accelerometer with multiple sensitivity ( ± 2, ± 4, ± 8 and ± 16 g), 13-bit triaxial magnetometer ( ± 1200 uT) and 16-bit/axis triaxial gyroscope with multiple sensitivity ( ± 250, ± 500, ± 1000 and ± 2000 °/s). The inertial sensor has been validated by Bugané and colleagues (19) . The IMU (BTS G-WALK) has specific hardware (BTS G-SENSOR) and software (BTS G-STUDIO).…”
Section: Six-minute Walk Test (6mwt) -The Six-minute Walkmentioning
confidence: 99%
“…The acceleration data will be transmitted via Bluetooth to a computer and processed using the software program designed for the system (BTS G-STUDIO, version 2.6.12.0), which automatically furnishes the parameters (18,19) . For the acquisition of the gait variables, the sensor will be connected to the participant's waist with a semi-elastic strap covering the intervertebral space between L4 and L5 (19) . During the walk test, the participant will be instructed to walk at his/her individualized normal pace over a pre-established track.…”
Section: Evaluation Of Gaitmentioning
confidence: 99%
“…Therefore, the distance between the two successive foot contacts on the ground was considered as the step length, while the distance between three successive foot contacts was considered as the stride length. The first and last steps of the 8-m walk were removed from all calculations considering the abnormal patterns at the initiation of gait or the psychological responses at the termination of gait 13) .…”
Section: ) Assessment Of Performance-based Physical Functionmentioning
confidence: 99%