Evaluation of a lithium formate EPR dosimetry system for dose measurements around brachytherapy sources

Abstract: A dosimetry system using lithium formate monohydrate ͑HCO 2 Li· H 2 O͒ as detector material and electron paramagnetic resonance ͑EPR͒ spectroscopy for readout has been used to measure absorbed dose distributions around clinical 192 Ir sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g / cm 3 were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam.192 Ir irradiations were performed in a PMMA phantom using two differ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
38
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 36 publications
(40 citation statements)
references
References 51 publications
2
38
0
Order By: Relevance
“…31 Experimental phantoms are usually cubic and commonly used TPSs use as references a water cylinder of diameter and height 40 cm ͑Varian for the GammaMed Plus and 12i sources [20][21][22] ͒ or a water sphere of diameter 30 cm ͑Nucletron for all their sources 17,32-34 ͒. Results…”
Section: Discussionmentioning
confidence: 99%
“…31 Experimental phantoms are usually cubic and commonly used TPSs use as references a water cylinder of diameter and height 40 cm ͑Varian for the GammaMed Plus and 12i sources [20][21][22] ͒ or a water sphere of diameter 30 cm ͑Nucletron for all their sources 17,32-34 ͒. Results…”
Section: Discussionmentioning
confidence: 99%
“…A BRUKER EleXsys E500 was used with a BRUKER standard resonator (4102ST) for all readouts. Details about the dosimeter manufacturing and handling can be found in earlier publications [10][11][12].…”
Section: Dosimeters and Epr Readoutmentioning
confidence: 99%
“…Lithium formate has previously been used for verification of IMRT treatments [10] and for measurement around 192 Ir brachytherapy sources [11]. The LET-dependence of response for photon energies < 150 keV relative to 60 Co is known [12] and imply that the lithium formate system is a good candidate for use also in brachytherapy audits.…”
Section: Introductionmentioning
confidence: 99%
“…Electron paramagnetic resonance, EPR, has long been used to map dose distributions in radiation therapy as for instance experimental verification of dose distributions around brachytherapy sources using alanine/agarose gel and alanine film (1) or lithium formate dosimeter tablets (2). An example of application in external beam therapy has been for verification measurements of intensity modulated radiotherapy (IMRT) dose plans, using lithium formate tablets (3).…”
Section: Introductionmentioning