“…Al respecto, las mediciones realizadas con el espermadensímetro están sujetas a fuentes de variabilidad externas, como partículas de suciedad, espermatozoides inmaduros, células sanguíneas y epiteliales, número de leucocitos y residuos celulares, que aumentarían la turbidez del semen y podría tenderse a sobrestimar los resultados (Eustache et al 2001). La estimación de la concentración con el espectrofotómetro fue la menor, sin embargo, mostró un coeficiente de variación del orden del 40%, que fue mayor que el reportado en otros trabajos con el mismo método (Zrimšek 2011). La curva de calibración de este instrumento puede influir en las mediciones y subestimar los resultados.…”
Section: Discussionunclassified
“…Al respecto, las mediciones realizadas con el espermadensímetro están sujetas a fuentes de variabilidad externas, como partículas de suciedad, espermatozoides inmaduros, células sanguíneas y epiteliales, número de leucocitos y residuos celulares, que aumentarían la turbidez del semen y podría tenderse a sobrestimar los resultados (Eustache et al 2001). La estimación de la concentración con el espectrofotómetro fue la menor, sin embargo, mostró un coeficiente de variación del orden del 40%, que fue mayor que el reportado en otros trabajos con el mismo método (Zrimšek 2011). La curva de calibración de este instrumento puede influir en las mediciones y subestimar los resultados.…”
Section: Discussionunclassified
“…A scatter diagram of the number of HRSH obtained using the classic manual method versus the filter-lysis automated method was fitted with a Deming regression line. In addition, a Bland-Altman plot was generated to determine the agreement between the classic manual and filter-lysis automated approaches (Zrimsek, 2011). …”
Section: Methodsmentioning
confidence: 99%
“…The use of a hemocytometer in this method necessitates that multiple counts be recorded due to the high levels of variation and error inherent in the technique. It has been previously reported that mean differences of greater than 20% are common in manual sperm counts, even when the counts are performed by the same individual (Freund and Carol, 1964, Zrimsek, 2011), highlighting the need for a reliable automated protocol.…”
Section: Introductionmentioning
confidence: 99%
“…Comparisons between sperm concentration estimates obtained using hemocytometers and those obtained using spectrophotometers revealed high correlation and regression coefficients (r and r 2 > 0.9) [41,61,62] and comparison of the means obtained using hemocytometers and a general purpose spectrophotometer for evaluation of raw bull semen revealed no significant differences between the methods [41]. In another study, the mean difference of paired results obtained using a Makler chamber and a commercial sperm concentration spectrophotometer for evaluation of boar semen was -0.6% with all results between -15 and 15% [63]. When different models of commercial sperm concentration spectrophotometers were used for evaluation of stallion semen, the results were consistently greater than that obtained with the hemocytometer for one model (range 9 to 17% depending on the concentration), consistently lower for two models (range -2% to -25%), and variable for another model (range -25% at high concentration to 26% at low concentration) [64].…”
Section: Precision and Accuracymentioning
confidence: 99%