1996
DOI: 10.1016/0009-8981(96)80001-e
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a rapid strip test for insulin-like growth factor binding protein-1 in the diagnosis of ruptured fetal membranes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
83
0
7

Year Published

2001
2001
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 89 publications
(94 citation statements)
references
References 13 publications
4
83
0
7
Order By: Relevance
“…Inter-and intraassay coefficients of variation were 4.9 -13% and 7.2-8.6%, respectively, and the detection limit was 120 g/L. The IGFBP-1-concentrations were determined by immunoenzymometric assay as described (36). Interand intraassay coefficients of variation were 7.4% and 3.4%, respectively, and the detection limit was 0.4 g/L.…”
Section: Biochemical Analysesmentioning
confidence: 99%
“…Inter-and intraassay coefficients of variation were 4.9 -13% and 7.2-8.6%, respectively, and the detection limit was 120 g/L. The IGFBP-1-concentrations were determined by immunoenzymometric assay as described (36). Interand intraassay coefficients of variation were 7.4% and 3.4%, respectively, and the detection limit was 0.4 g/L.…”
Section: Biochemical Analysesmentioning
confidence: 99%
“…Only prospective observational or cohort studies that met the following criteria were included in the meta-analysis: (1) the performance metrics were calculated by comparing the results with an adequate reference method for the diagnosis of ROM as defined later; (2) the investigated test(s) had sensitivity thresholds matching those of the currently available tests for the respective antigens: 5 ng/mL in vivo for PAMG-1 [8] and 400 ng/mL in vivo for IGFBP-1 (i.e., 25 ng/mL in vitro ) [41] ; and (3) the study population included (but was not confined to) patients between 25 and 37 weeks of gestation.…”
Section: Study Selectionmentioning
confidence: 99%
“…It is noted that this study could have been eliminated from further evaluation during the second filter instead of the third because although the IGFBP-1 test used had a detection threshold matching that of the commercially available kit for IGFBP-1, the test was performed by placing the testing strip directly into the cervical os and posterior fornix of the vagina without the use of the collection swab [1] . Given that Rutanen et al [41] highlighted that the swab is responsible for a 1:16 dilution of the sample, the use of the test without the swab lowers the detection threshold of the test quite substantially.…”
Section: Study Selectionmentioning
confidence: 99%
See 1 more Smart Citation
“…PEMR hâlâ pek çok açıdan bilinmezliğini korumaktadır. Şimdiye dek şüpheli EMR olgularına tanı koymak amaçlı amnion mayiinde birçok madde üzerinde çalışılmıştır (6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22) . Bunlardan bir tanesi de amnion mayiinde laktat konsantrasyonunun ölçümüdür (23) .…”
Section: Introductionunclassified