Abstract: The suitability of a new technology single-monochromator diode array spectroradiometer for UV-radiation safety measurements, in particular for sunbed measurements, was evaluated. The linearity, cosine response, temperature response, wavelength scale, stray-light and slit function of the spectroradiometer were determined and their effects on the measurement accuracy evaluated. The main error sources were stray-light and nonideal cosine response, for which correction methods are presented. Without correction, th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
45
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 48 publications
(47 citation statements)
references
References 8 publications
2
45
0
Order By: Relevance
“…Nuclear Safety Authority (STUK) (Ylianttila, Visuri, Huurto, & Jokela, 2005) prior to the measurements in early spring, to allow accurate recording of outdoor solar radiation from the UV-B to the near-infrared.…”
Section: The Spectroradiometer Was Calibrated By the Finnish Radiatiomentioning
confidence: 99%
“…Nuclear Safety Authority (STUK) (Ylianttila, Visuri, Huurto, & Jokela, 2005) prior to the measurements in early spring, to allow accurate recording of outdoor solar radiation from the UV-B to the near-infrared.…”
Section: The Spectroradiometer Was Calibrated By the Finnish Radiatiomentioning
confidence: 99%
“…Fortunately, these individual tests are carried out usually For determination of spectral responsivity of a radiometer, it is usually calibrated against a known source placed at a specified distance from the entrance optics of the radiometer. Such a calibration procedure is well established and validated [6][7][8][9][10][11][12]. Unfortunately, specified conditions during the calibration may be quite different from varying conditions which may prevail during later use of the instrument.…”
Section: Introductionmentioning
confidence: 99%
“…The spectrum of the narrowband UVB lamps is presented in Figure . Uncertainty (2σ) of the measurement of the OceanOptics S2000 was estimated to be approximately 14% . The measurements are traceable to the National Institute of Standards and Technology (Gaithersburg, MD, USA).…”
Section: Methodsmentioning
confidence: 99%