2013
DOI: 10.1016/j.solener.2013.01.018
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of adding flash tank to solar combined ejector–absorption refrigeration system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 47 publications
(12 citation statements)
references
References 42 publications
0
12
0
Order By: Relevance
“…However, the COP of the system strongly depends on the ejector performance [113] and, therefore, detailed models for the off-design of the component should be developed along with an optimization of the ejector geometry [132]. When considering hot climates, in which the condenser has a lower efficiency, the solution proposed by Sirwan et al [204] may enable the system to perform well. A summary of the EAbRS studies is presented in Table 8.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the COP of the system strongly depends on the ejector performance [113] and, therefore, detailed models for the off-design of the component should be developed along with an optimization of the ejector geometry [132]. When considering hot climates, in which the condenser has a lower efficiency, the solution proposed by Sirwan et al [204] may enable the system to perform well. A summary of the EAbRS studies is presented in Table 8.…”
Section: Discussionmentioning
confidence: 99%
“…These concerns can be relieved with additional research on new mixtures of HCs and HFCs [8]. Another working fluid that has been studied is ammonia (R717) [106,130,139,144,146,149,157,192,[202][203][204][205] for its low cost, high performance and more favorable thermodynamic properties, and it does not create environmental problems. However, it likely will remain restricted to industrial applications, as it is unsuitable for domestic use due to its toxicity [13].…”
Section: Working Fluids In Ejector Refrigerationmentioning
confidence: 99%
See 1 more Smart Citation
“…In his model the secondary flow of the ejector is directly linked with the low pressure streamline of the evaporator. Sirwan et al [34,35] showed that the performance of a combined absorption-ejector cooling cycle can be enhanced further by adding a flash tank to the cycle. However, some limitation on the ejector efficiency is …”
Section: Introductionmentioning
confidence: 99%
“…Combined flash tank-absorption-ejector cooling system[34] Schematic diagram of the proposed combined absorption cooling cycle. : a ) Single pass shell and tube heat eachanger , b) Pressure-Enthalpy diagram2.2.…”
mentioning
confidence: 99%