Evaluation of ahmed glaucoma valve implantation through a needle-generated scleral tunnel in Mexican children with glaucoma

Abstract: Purpose:To evaluate the results and extrusion rates of the Ahmed glaucoma valve (AGV) implantation through a needle-generated scleral tunnel, without a tube-covering patch, in children.Materials and Methods:A retrospective review of the charts of 106 Mexican children implanted with 128 AGVs operated between 1994 and 2002, with the needle track technique, at our institution, with at least six months follow up was done. Main outcome measures were intraocular pressure (IOP) control, tube extrusions or exposure an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 35 publications
(37 citation statements)
references
References 18 publications
0
36
1
Order By: Relevance
“…None of the patient had tube extrusion during the 6-month follow-up. 69 Although the result is not statistically significant due to the small sampling size (CI < 1.5%), the study sheds insight to the alternative methods of GDD insertion.…”
Section: Treatmentmentioning
confidence: 69%
“…None of the patient had tube extrusion during the 6-month follow-up. 69 Although the result is not statistically significant due to the small sampling size (CI < 1.5%), the study sheds insight to the alternative methods of GDD insertion.…”
Section: Treatmentmentioning
confidence: 69%
“…[32] An alternative long intrascleral tunnel technique without patch has been described with good midterm results. [33]…”
Section: Tube Insertionmentioning
confidence: 99%
“…On the other hand, the lack of tube extrusions and exposures is actually closer to truth, since any such complication would need a surgical procedure that would necessarily be recorded at the chart; our patchless technique has been reported to have a low rate of tube extrusions/exposure. 19 35…”
Section: Discussionmentioning
confidence: 99%
“…The surgical technique used in these cases has been described in detail elsewhere and does not involve use of a scleral patch graft. 17 - 19 In brief, a fornix-based conjunctival flap was created in the superotemporal quadrant and the Ahmed plate was sutured to the scleral bed 8 to 10 mm behind the limbus with 7-0 silk. A scleral tunnel initiated 3 to 4 mm from the limbus was constructed using a 23 G needle, bent in a ‘Z’ formation to avoid interference from the eyelids, brow or lid speculum.…”
Section: Methodsmentioning