2014
DOI: 10.1016/j.renene.2014.03.049
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of cascaded H-bridge inverter for utility-scale photovoltaic systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 79 publications
(28 citation statements)
references
References 7 publications
0
21
0
Order By: Relevance
“…The objective is to obtain the diagonal matrix in the series combination, between the matrix of the decoupling network and the matrix of the current-loop closed system [38]. In the inverted decoupling method, the off-diagonal elements are derived as (24) and (25).…”
Section: Voltage Controller Design Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The objective is to obtain the diagonal matrix in the series combination, between the matrix of the decoupling network and the matrix of the current-loop closed system [38]. In the inverted decoupling method, the off-diagonal elements are derived as (24) and (25).…”
Section: Voltage Controller Design Methodsmentioning
confidence: 99%
“…The multi-level converter has been used mainly in renewable energy systems using high-voltage above kV, but researches are expanding to low-voltage applications to take advantage of the aforementioned merits [16,17]. Among several studies, because isolated direct current (DC) sources are naturally obtained from the photovoltaic (PV) arrays, and can be easily modularized compared to other multilevel converters, a PV generation system with the cascaded H-bridge multilevel inverter topology has been studied [16][17][18][19][20][21][22][23][24][25]. Reference [16] presented a study on the reactive power compensation for the single phase grid-connected cascaded H-bridge multilevel inverter, but they did not fully suggest the method for designing the controller.…”
Section: Introductionmentioning
confidence: 99%
“…In Design calculations for CHB inverters, selection of devices, device loss calculations etc. are discussed in [16,17]. The procedure for the selection of CHB inverter and AC side filter components is shown in Table 1.…”
Section: Design Calculations For the Systemmentioning
confidence: 99%
“…The switches in the CHMLI support the same voltage stress. This multilevel inverter can use directly DC sources to generate staircase voltage levels and continue to operate even when a full bridge is shutdown [4]- [7]. The cascaded H-Bridge multilevel inverter is frequently studied for command improvement involving synchronization strategy and output voltage power levels enhancement [8]- [9].…”
Section: Introductionmentioning
confidence: 99%