1985
DOI: 10.1016/0004-6981(85)90229-x
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of cyclone performance in different gases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1990
1990
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…This kind of cyclone (shown in Figure 1a) is a typical reversed ow or cone-under-cylinde r design. The performance of the high efciency Stairmand cyclone has been studied extensively through both laboratory and eld works (Dietz 1981;Boysan et al 1982;Dirgo and Leith 1985;Lee et al 1985;Iozia and Leith 1989;Li and Wang 1989;Iozia and Leith 1990;Kim and Lee 1990;Coker 1993;Liden and Gudmundsson 1997;Zhu and Lee 1999). Several other cyclone designs have been evaluated by comparing their performance with that of the high ef ciency Stairmand cyclone (Razgaitis and Gusenther 1981; Jaroszczyk and Ptak 1985;Moore and McFarland 1990).…”
Section: High Ef Ciency Stairmand Cyclonementioning
confidence: 99%
See 1 more Smart Citation
“…This kind of cyclone (shown in Figure 1a) is a typical reversed ow or cone-under-cylinde r design. The performance of the high efciency Stairmand cyclone has been studied extensively through both laboratory and eld works (Dietz 1981;Boysan et al 1982;Dirgo and Leith 1985;Lee et al 1985;Iozia and Leith 1989;Li and Wang 1989;Iozia and Leith 1990;Kim and Lee 1990;Coker 1993;Liden and Gudmundsson 1997;Zhu and Lee 1999). Several other cyclone designs have been evaluated by comparing their performance with that of the high ef ciency Stairmand cyclone (Razgaitis and Gusenther 1981; Jaroszczyk and Ptak 1985;Moore and McFarland 1990).…”
Section: High Ef Ciency Stairmand Cyclonementioning
confidence: 99%
“…Since cyclones have been used extensively in industry, both theoretical and experimental studies on cyclones were carried out from the early 1940s to the present (Stairmand 1951;Dietz 1981;Boysan et al 1982;Dirgo and Leith 1985;Lee et al 1985;Iozia and Leith 1989;Li and Wang 1989;Iozia and Leith 1990;Kim and Lee 1990;Coker 1993;Liden and Gudmundsson 1997;Zhu and Lee 1999). Although our knowledge of ow and particle capture mechanisms operating inside a cyclone has increased over the years, the exact mechanisms of removing particles are still not fully understood.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, the boiler operational conditions as well as the black liquor properties were simultaneously recorded. The particles were extracted from the flue gas with a quench probe or a dilution system and collected on quartz filters, size classified with a Berner-type low-pressure impactor down to 0.01 μm particle diameter and with a three-stage cyclone system . Samples were collected on copper grids or on planar filters for electron microscope analyses.…”
Section: Introductionmentioning