2020
DOI: 10.1016/j.ajo.2020.03.025
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Long-Term Visual Field Function in Patients Undergoing Glaucoma Drainage Device Implantation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 30 publications
0
7
0
Order By: Relevance
“…Additionally, this platform can potentially be used in conjunction with other analysis platforms such as the R package visualField (an open source module for analysis of visual field data), with the appropriate software to interface the two systems ( 24 ). Our platform has been used in a published study on HVFs in glaucoma patients undergoing glaucoma tube shunt implantation ( 25 ). Other research teams have performed studies with large volumes of HVFs for metric analysis and machine learning using in-house extraction software ( 6 , 11 ); however, their script was not published and validation cannot be compared with ours.…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, this platform can potentially be used in conjunction with other analysis platforms such as the R package visualField (an open source module for analysis of visual field data), with the appropriate software to interface the two systems ( 24 ). Our platform has been used in a published study on HVFs in glaucoma patients undergoing glaucoma tube shunt implantation ( 25 ). Other research teams have performed studies with large volumes of HVFs for metric analysis and machine learning using in-house extraction software ( 6 , 11 ); however, their script was not published and validation cannot be compared with ours.…”
Section: Discussionmentioning
confidence: 99%
“…When IOP can no longer be controlled with medications surgical intervention is required, which often is not a permanent solution [43]. It is, therefore, essential to develop novel drugs that modulate the metabolic processes of trabecular meshwork, ciliary body, and retinal cells.…”
Section: Discussionmentioning
confidence: 99%
“…Production in-creased by 158% whereas outflow increased by 342%, a net 185% increase in outflow. In the untreated eye both flow and outflow decreased from the pre-treatment values, which may be the result of diurnal fluctuations [42,43]. Eight hours after administration, IOP was 20% lower than 30 minutes after administration of a 0.5% suspension of tolbutamide and 24% lower after the administration of a 0.5% solution of sodium tolbutamide.…”
Section: Effect Of 05% Tolbutamide On Aqueous Humor Outflow Facilitymentioning
confidence: 94%
“…The sector wise values were then calculated by averaging the pointwise values across each sector based on prior established sectorial mapping. 20 Each VF hemifield was divided into five subfields: central, paracentral, nasal, arcuate 1, and arcuate 2 ( Figure 1 ), as previously described. 20 For 30–2 VF test, only data for points falling within the 24–2 domain were collected.…”
Section: Methodsmentioning
confidence: 99%
“… 20 Each VF hemifield was divided into five subfields: central, paracentral, nasal, arcuate 1, and arcuate 2 ( Figure 1 ), as previously described. 20 For 30–2 VF test, only data for points falling within the 24–2 domain were collected. Analysis of VF defects was carried out based on the classification system proposed by the Ocular Hypertension Treatment study.…”
Section: Methodsmentioning
confidence: 99%