2008
DOI: 10.1117/12.770571
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
58
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
4
2
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 54 publications
(60 citation statements)
references
References 4 publications
1
58
0
1
Order By: Relevance
“…CDMAM is the accepted European standard for evaluating FFDM image quality [24] and utilizes freely available software to automatically process the images [25]. Zerdine, which simulates the acoustic properties of breast tissue, is used in the construction of the CIRS phantom, which also includes a variety of targets that mimic breast lesions.…”
Section: Phantom Testingmentioning
confidence: 99%
See 1 more Smart Citation
“…CDMAM is the accepted European standard for evaluating FFDM image quality [24] and utilizes freely available software to automatically process the images [25]. Zerdine, which simulates the acoustic properties of breast tissue, is used in the construction of the CIRS phantom, which also includes a variety of targets that mimic breast lesions.…”
Section: Phantom Testingmentioning
confidence: 99%
“…The threshold gold thickness has been plotted as a function of detail diameter, using a logarithmic scale for both axes. The Aceso data are based on eight sequential X-ray images (at 33 kV, 30 mAs, 2.4 mGy) and may be compared with the EUREF standards of "acceptable" and "achievable" [24]. data was performed.…”
Section: Two Clinical Examplesmentioning
confidence: 99%
“…A set of 32 images was acquired for each of the CDMAM 3.4 phantoms and each of the mammography units. A relatively large number of images improves the reproducibility of the analysis process for all detail sizes [7]. All of the images were obtained in an unprocessed study (QC-RAW) for identical exposure parameters: 28 kV, 140 mAs (manual mode), W/Rh anode/fi lter combination, with an antiscatter grid.…”
Section: Images Of the Cdmam 34 Phantomsmentioning
confidence: 99%
“…In the original method, visibility was determined visually by a group of three human observers [1]. However, studies have shown the inter-and intraobserver variability in the assessment of the structures in the CDMAM phantom images [7,8]. To eliminate the infl uence of the human factor, several computer programs to analyze the CDMAM phantom images have been developed.…”
mentioning
confidence: 99%
“…As tecnologias que favorecem a aquisição de mamografias no formato digital tornaram possível a automatização destes procedimentos e tem sido alvo de diversos pesquisadores que vêm se empenhando na tentativa de se criar uma ferramenta computacional precisa e adequada à rotina de controle de qualidade (PRIETO et al, 2008;YOUNG et al, 2008;YIP et al, 2009). …”
Section: Capítulo 5 Materiais E Métodosunclassified