This study is the first part of a larger investigation into the fire behaviour of green façades. In this study, the currently known international research status on this topic is presented and discussed. In addition, the flammability of green façades is investigated through 43 fire tests on a medium scale according to the SBI (Single Burning Item) test method EN 13823. The focus of the investigation was placed on climbing plants. A total of 25 different plant species were investigated. A comparison of the heat release rate of all the investigated vital plants shows similar behaviour. In the course of exposure, there are short peaks in the heat release rate. These peaks are “flare-ups” that occur when parts of the plants dry out due to exposure to the flame and then ignite. The plant species itself had no substantial influence on fire behaviour. Horizontal fire spread occurred to a very limited extent within the investigations of vital plants. They were self-extinguishing. The significant factor in the assessment of flammability is the moisture content of the plants. With dried plants, an abrupt heat release occurs at the beginning. Dried-out plants, as well as unmaintained plants with a high content of deadwood, represent the most critical case.