Evaluation of the Technical Condition of the Active Part of the High Power Transformer Based on Measurements and Analysis of Vibroacoustic Signals

Abstract: This article presents the results of research connected with the development and industrial use of vibroacoustic methods for the evaluation of the technical condition of the active part of transformers. The article presents the results of the analysis of vibrations generated by the high power transformer in which a defect was found on the basis of tests of oil carried out using the chromatography tests. In order to confirm the damage of the active part of this transformer, vibroacoustic measurements were perfo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 8 publications
0
11
0
Order By: Relevance
“…In the currently used approach to the analysis of vibroacoustic signals coming from the transformer [17][18][19][20], relatively high criteria values are adopted (the normal state is determined up to the value of 400 cm/s 2 of total RMS of vibration acceleration, while the emergency state is determined after exceeding 2500 cm/s 2 ). The values of vibration accelerations measured by the authors for the 12 non-repaired transformers in service range from about 10 to 395 cm/s 2 , so all these units are in a normal state, even transformers over 45 years in use.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…In the currently used approach to the analysis of vibroacoustic signals coming from the transformer [17][18][19][20], relatively high criteria values are adopted (the normal state is determined up to the value of 400 cm/s 2 of total RMS of vibration acceleration, while the emergency state is determined after exceeding 2500 cm/s 2 ). The values of vibration accelerations measured by the authors for the 12 non-repaired transformers in service range from about 10 to 395 cm/s 2 , so all these units are in a normal state, even transformers over 45 years in use.…”
Section: Discussionmentioning
confidence: 99%
“…In the works [17][18][19][20] we can find information about the transformer vibrations sources that has been assigned appropriate frequency ranges in the vibration spectrum:…”
Section: Related Workmentioning
confidence: 99%
See 2 more Smart Citations
“…Dedicated methods were developed on the basis of phenomena accompanying ED and make it possible to detect and measure these phenomena, as well as locate the place of their occurrence. The following methods are currently used in the diagnostics of insulation systems in power devices: electrical method, acoustic emission method, ultra-high frequency method, gas chromatography method [1][2][3][4][5][6][7][8][9][10][11][12][13] and alternative methods, basis of the time difference on an energy accumulation curve of multiple signals [14].…”
Section: Introductionmentioning
confidence: 99%