Abstract: A general outline of the development of PD diagnostics is given with emphasis on problems of the validity of underlying models and the interpretation of results, because PD diagnostics is hardly ever direct and instead rests on a chain of inferences. Some major classical approaches are reviewed in this context, with a discussion of certain problems that also are significant for modern approaches. After a discussion of primary PD events and resulting degradation, some basic matters regarding measurement and tes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0
2

Year Published

1997
1997
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 75 publications
1
5
0
2
Order By: Relevance
“…Particle velocities of each dimension are tried to a maximum velocity . If the sum of velocities causes the total velocity of that dimension to exceed , then the velocity of that dimension is limited to , since , 4, 4 , the inertia weight factor is taken as (1).…”
Section: Appendix IImentioning
confidence: 99%
See 1 more Smart Citation
“…Particle velocities of each dimension are tried to a maximum velocity . If the sum of velocities causes the total velocity of that dimension to exceed , then the velocity of that dimension is limited to , since , 4, 4 , the inertia weight factor is taken as (1).…”
Section: Appendix IImentioning
confidence: 99%
“…Partial Discharge (PD) measurements, an established flaw detection technique, provide means for assessing the integrity of insulation systems. Researchers and practitioners have long exploited the diversity in measurement techniques as well as interpretation of the recorded PD data [1][2][3][4][5] to monitor the performance of power transformer: both offline and in real time.…”
Section: Introductionmentioning
confidence: 99%
“…The characteristics of IDs and PD detection techniques were particularly studied in the last forty years [5][6][7][8][9]. Special emphasis has been given in the last 15 or so years in the development of PD detection techniques by using Pulse Height Analysis as well as Phase Resolved Measurement techniques [16]. Efforts have been made in the course of years to relate PD magnitude, energy and other parameters to insulation damage [14,15].…”
Section: Introductionmentioning
confidence: 99%
“…Portanto, a simples operação do circuito equivalente não corresponde, necessariamente, a gama de processos físicos que se desenvolvem em um sistema físico real (KELEN et al, 1995;McALLISTER, 1997;PEDERSEN et al, 1991). Buscando-se uma representação mais próxima do real, outros modelos têm sido propostos.…”
Section: Dps Em Tensões Alternadasunclassified