2012
DOI: 10.2174/1874325001206010001
|View full text |Cite
|
Sign up to set email alerts
|

Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development

Abstract: Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical application of an anatomically pre-contoured plate for the treatment of distal fibular fractures based on the anatomical dat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
19
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(19 citation statements)
references
References 19 publications
0
19
0
Order By: Relevance
“…Several definition methods for the fit optimization of a precontoured fracture fixation plate for a given bone data set have been presented in the literature. [13][14][15][16][17][18][19] In most of them, the fitting of the plate to the bone is conducted entirely in a virtual environment utilizing computer graphical methods and three-dimensional bone and plate models based on computer tomography scans. In contrast to these studies in which the computer places the plate in the best position, in our study, the plate was placed over the bone as was implemented in actual surgery.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Several definition methods for the fit optimization of a precontoured fracture fixation plate for a given bone data set have been presented in the literature. [13][14][15][16][17][18][19] In most of them, the fitting of the plate to the bone is conducted entirely in a virtual environment utilizing computer graphical methods and three-dimensional bone and plate models based on computer tomography scans. In contrast to these studies in which the computer places the plate in the best position, in our study, the plate was placed over the bone as was implemented in actual surgery.…”
Section: Discussionmentioning
confidence: 99%
“…The mean distance between the plate surface and the underlying bone surface, [15][16][17] the maximum distance between the plate and the underlying bone surface, [18,19] and also the volume between the plate and underlying bone surface [13] were used as fit assessment parameters. Furthermore, qualitative evaluation was used in some studies.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Osteosynthesis plates with high levels of anatomical compliance (i.e., plates which exhibit a small distance between bone surface and plate for a large number of patients) have been demonstrated to have numerous clinical benefits. With regard to aspects related to the surgical procedure itself, use of anatomically enhanced plate designs may allow for increased opportunities for the use of minimally invasive operative techniques . Furthermore, such plates require little to no intra‐operative bending, which is advantageous as bending has the potential to decrease the mechanical stability of the plate, which may result in an increased risk of implant failure .…”
mentioning
confidence: 99%