Evolution and Future of Preclinical Testing for Endovascular Grafts

Abstract: The preclinical testing of endovascular grafts has evolved significantly since the creation and early testing of these devices; however, there are continued limitations in using preclinical testing to predict clinical performance. Early testing was conducted in the absence of standards and guidance specific to endovascular grafts, and references available for vascular grafts and stents did not adequately account for the complexity of endovascular graft systems. Failure of early-generation devices suggested tha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(19 citation statements)
references
References 4 publications
0
18
0
1
Order By: Relevance
“…However, twisting may cause yarn shifting, possibly allowing blood percolation through the fabric. Percolation of low volumes of blood through multiple sites of damage to the fabric may explain the endotension phenomenon [59,60,61,62,63,64,65,66,67,68,69,70,71,72,73,74,75,76,77,78,79,80,81,82,83,84]. …”
Section: Discussionmentioning
confidence: 99%
“…However, twisting may cause yarn shifting, possibly allowing blood percolation through the fabric. Percolation of low volumes of blood through multiple sites of damage to the fabric may explain the endotension phenomenon [59,60,61,62,63,64,65,66,67,68,69,70,71,72,73,74,75,76,77,78,79,80,81,82,83,84]. …”
Section: Discussionmentioning
confidence: 99%
“…Une autre application est l'évaluation des stents grafts thoraciques. En effet, les différents constructeurs ont proposé des modèles in vitro pour évaluer leurs dispositifs mais la plupart de ces évaluations sont souvent très loin de la réalité à la fois sur le plan de l'anatomie que sur le plan des caractéristiques physiologiques de ces modèles (24). L'intérêt des CFD est d'évaluer sur des patients, les différents matériels qui peuvent être utilisés pour analyser la réponse entre la prothèse et la paroi aortique mais également pour analyser les mouvements et les forces pariétales exercées par le flux sanguin au sein du stent graft et ainsi d'apprécier les risques de lésions de fatigue du matériel ( fig.…”
Section: Discussionunclassified
“…All new devices need to be evaluated, as preclinical testing may be useful to screen out poor designs prior to clinical use, and after the first clinical trials animal testing could help in analysing clinically observed failures and in evaluating device modifications. 7 Minimally Invasive procedures for AAA therapy, including laparoscopy, 8 are relatively new, and are therefore still under development. An animal model of AAA that could be used both in research and training in these procedures would be helpful in defining the role of each technique, as well as in exploring future possibilities, such as combined therapies, both in terms of combining endovascular with laparoscopic approaches and in regards to the use of drug-eluting stent grafts.…”
Section: Introductionmentioning
confidence: 99%
“…An animal model of AAA that could be used both in research and training in these procedures would be helpful in defining the role of each technique, as well as in exploring future possibilities, such as combined therapies, both in terms of combining endovascular with laparoscopic approaches and in regards to the use of drug-eluting stent grafts. 7 It has been recommended that animal studies of endovascular grafts focus on the assessment of the delivery systems and biological responses to the device. 7 Different animal models of AAA have been described in the literature.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation