2013
DOI: 10.1016/j.corsci.2013.06.052
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and theoretical studies for mild steel corrosion inhibition in 1M HCl by two new benzothiazine derivatives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
48
1
3

Year Published

2014
2014
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 139 publications
(54 citation statements)
references
References 43 publications
2
48
1
3
Order By: Relevance
“…For a quantitative evaluation of the effects of castor bark powder addition in the corrosion resistance of the CS AISI 1020, impedance diagrams were fitted using the electrical equivalent circuit (EEC) presented in Figure 4. The model is composed by a single time constant and has been commonly used to fit impedance diagrams of CS in acidic solutions, without or with inhibitor addition 17,32,[42][43][44] . In the circuit, R S is the solution resistance, R ct the charge transfer resistance and CPE dl is a constant phase element (CPE) accounting for the double layer capacity.…”
Section: Electrochemical Impedance Spectroscopy (Eis)mentioning
confidence: 99%
See 1 more Smart Citation
“…For a quantitative evaluation of the effects of castor bark powder addition in the corrosion resistance of the CS AISI 1020, impedance diagrams were fitted using the electrical equivalent circuit (EEC) presented in Figure 4. The model is composed by a single time constant and has been commonly used to fit impedance diagrams of CS in acidic solutions, without or with inhibitor addition 17,32,[42][43][44] . In the circuit, R S is the solution resistance, R ct the charge transfer resistance and CPE dl is a constant phase element (CPE) accounting for the double layer capacity.…”
Section: Electrochemical Impedance Spectroscopy (Eis)mentioning
confidence: 99%
“…Therefore, modifications of the parameters ε and d can produce changes in C dl , which in Table 3 is proportional to CPE dl . Water molecules and/or chloride ions can be displaced from the electrode surface by the inhibitors molecules 44 , thus diminishing the dielectric constant of the double layer. In addition, the bigger size of the organic molecules with…”
mentioning
confidence: 99%
“…. In the circuit, R s stands for the solution resistance, R ct represents the charge transfer resistance and CPE dl is a constant phase element representing the double layer charging, which accounts for frequency dispersion in the EIS response, usually ascribed to physical phenomena like roughness or non-homogeneity of the surface 32 . The impedance of a CPE is defined by Eq.…”
Section: Gravimetric Methodsmentioning
confidence: 99%
“…33 The shape of the Nyquist doesn't change before and after the addition of HMTH, which demonstrates that the corrosion mechanism of carbon steel remains the same. 37 Yet, the diameter of the capacitive loops in the presence of HMTH is quite bigger than that in the absence of HMTH and increases with the inhibitor concentration, which can be ascribed to the forming of the protective layer on the carbon steel surface. All capacitive loops of EIS spectra were analyzed using the equivalent circuit in Fig.…”
Section: Potentiodynamic Polarization Curvesmentioning
confidence: 99%