2014
DOI: 10.1080/01932691.2013.879831
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and Theoretical Studies on Synthesized Compounds as Corrosion Inhibitor for Mild Steel in Hydrochloric Acid Solution

Abstract: Imidazole derivatives, namely, 1-((1-(piperazinomethyl)-1H-benzoimidazol-2-yl)methyl)-2-phenylhydrazine (PBIP), and 1-((1-(morpholinomethyl)-1H-benzoimidazol-2-yl)methyl)-2-phenylhydrazine (MBIP) were synthesized and investigated as inhibitors for mild steel corrosion in 15% HCl solution using weight loss, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS) techniques. It was found that the inhibition efficiency of both the inhibitors increases with increase in concentration of inhib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 41 publications
0
5
0
1
Order By: Relevance
“…The estimated activation energies for the all the inhibited solutions was found to be greater in comparison to the solution with bare acid, as summarized in Table . Higher the value of activation energy, E a corresponds to increase in the energy barrier for the corrosion phenomenon. , As a result, inhibition efficiency is increased in the case of inhibited systems.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The estimated activation energies for the all the inhibited solutions was found to be greater in comparison to the solution with bare acid, as summarized in Table . Higher the value of activation energy, E a corresponds to increase in the energy barrier for the corrosion phenomenon. , As a result, inhibition efficiency is increased in the case of inhibited systems.…”
Section: Resultsmentioning
confidence: 99%
“…Higher the value of activation energy, E a corresponds to increase in the energy barrier for the corrosion phenomenon. 27,28 As a result, inhibition efficiency is increased in the case of inhibited systems.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The absolute values of DG 0 ads are in the range of À35.00 to À40.72 kJ/mol which is within the threshold value interpreted in the corrosion literature for comprehensive mode of adsorption (i.e. both physical and chemical adsorption) [49,50]. Meanwhile, a close inspection of Table 4 reveals that at lower temperature, physical adsorption mechanism prevails over chemical adsorption and DG 0 ads values become less negative.…”
Section: Adsorption Phenomenonmentioning
confidence: 90%
“…Analisando o diagrama de Bode na Figura 44 para os tempos de 3 e 6 horas, nota-se que o diagrama do sistema CMC_SDF é semelhante ao diagrama do sistema SMC_SDF e apresentam a mesma ordem de grandeza para os valores de |Z| na região de baixa frequência. Logo, conclui-se que as propriedades de barreira de ambos os filmes são semelhantes e que a adição das microcápsulas não prejudicou essa importante característica da tinta.Em relação ao sistema CMC_SDF, nota-se que a diminuição da resistência é mais lenta, pois em 9 horas de imersão a resistência ainda apresenta valores com ordem de grandeza de 10 9 e apenas em24 horas de imersão diminui para 8,64 x10 8 Ω.cm 2 . transferência de carga.…”
unclassified