2013
DOI: 10.1016/j.dental.2013.04.001
|View full text |Cite
|
Sign up to set email alerts
|

Experimental etch-and-rinse adhesives doped with bioactive calcium silicate-based micro-fillers to generate therapeutic resin–dentin interfaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
64
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 66 publications
(66 citation statements)
references
References 53 publications
2
64
0
Order By: Relevance
“…This hypothesis was also validated when immersing the specimens in the xylenol orange solution (Profeta et al, 2013;Toledano et al, 2013). In general, load cycled specimens treated with XO-dye produced a clearly outlined fluorescence due to a consistent Ca-minerals deposited within the bonding interface and inside the dentinal When specimens were load cycled in held 24 h, the complex moduli achieved at peritubular and intertubular dentine attained the highest values (68.45 and 80.62 GPa, respectively) among all tests, and it was ~2.74 and 4.72 fold higher than values attained in the unloaded groups (25 and 17 GPa, respectively).…”
Section: Resultsmentioning
confidence: 90%
See 1 more Smart Citation
“…This hypothesis was also validated when immersing the specimens in the xylenol orange solution (Profeta et al, 2013;Toledano et al, 2013). In general, load cycled specimens treated with XO-dye produced a clearly outlined fluorescence due to a consistent Ca-minerals deposited within the bonding interface and inside the dentinal When specimens were load cycled in held 24 h, the complex moduli achieved at peritubular and intertubular dentine attained the highest values (68.45 and 80.62 GPa, respectively) among all tests, and it was ~2.74 and 4.72 fold higher than values attained in the unloaded groups (25 and 17 GPa, respectively).…”
Section: Resultsmentioning
confidence: 90%
“…When sustained load was applied for 72 h, a tight fluorescein sorption throughout the thickness of the HL was detected, which extended until the total adhesive thickness, but it was more concentrated in the dentine vicinity (Figs 3/5A, 3/5B). In some tubules, a discrete spectral overlap (yellow) was appreciated in the emission of profile of both dyes (red and green), indicating further pathways of water uptake, presence of micro-canals for the advance of permeability and future degradation of the dentine-polymer interaction through nanoleakage (Profeta et al, 2013;Toledano et al, 2013). This mineral depleted and non-sufficiently infiltrated etched dentine was also observable as a dentine substrate scarcely remineralised, at both intertubular and peritubular locations (Fig 2E), indicating the pathway for further degradation.…”
Section: Resultsmentioning
confidence: 99%
“…The rest of the molars were immersed in 0.5 wt% xylenol orange solution (Xo: Sigma-Aldrich Chemie Gmbh, Riedstr, Germany), excited at 514-nm for 24 h at 37 ºC (pH 7.2). The latter is a calcium-chelator fluorophore commonly used in hard tissues remineralization studies, due to its ability to form complexes with divalent calcium ions (Profeta et al, 2013). Specimens were copiously rinsed with water and treated in an ultrasonic water bath for 2 min.…”
Section: Confocal Microscopy Evaluationmentioning
confidence: 99%
“…The resolution of CLSM images was 1024 x 1024 pixels. Five optical images were randomly captured from each resin-dentin interface, and micrographs representing the most common features of nanoleakage observed along the bonded interfaces were selected (Profeta et al, 2013;Toledano et al, 2013b). Three specimens from each subgroup were immersed.…”
Section: Confocal Microscopy Evaluationmentioning
confidence: 99%
See 1 more Smart Citation