2018
DOI: 10.1016/j.applthermaleng.2017.09.105
|View full text |Cite
|
Sign up to set email alerts
|

Experimental evaluation of a solid desiccant system integrated with cross flow Maisotsenko cycle evaporative cooler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 89 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…Desiccant cooling systems in different configurations with an indirect evaporative air cooling have been investigated by many authors in the past. Kashif Shahzad et al [52] compared a solid desiccant dehumidifier integrated with a cross flow Maisotsenko cycle heat and mass exchanger (HMX) with a traditional desiccant air conditioning system integrated with a direct evaporative cooler under different operating conditions and the same process and return airflow rates. It was found out that for the same supply airflow and regenerative airflow parameters, the first system was approximately 60-65% more efficient than the second one.…”
Section: Desiccant Systemsmentioning
confidence: 99%
“…Desiccant cooling systems in different configurations with an indirect evaporative air cooling have been investigated by many authors in the past. Kashif Shahzad et al [52] compared a solid desiccant dehumidifier integrated with a cross flow Maisotsenko cycle heat and mass exchanger (HMX) with a traditional desiccant air conditioning system integrated with a direct evaporative cooler under different operating conditions and the same process and return airflow rates. It was found out that for the same supply airflow and regenerative airflow parameters, the first system was approximately 60-65% more efficient than the second one.…”
Section: Desiccant Systemsmentioning
confidence: 99%
“…A combination of dehumidification and evaporative cooling could greatly enhance the cooling capacity and energy efficiency by 70% to 135%, respectively, according to the moisture removal rate. Kashif Shahzad et al [88] conducted an experimental evaluation of a solid desiccant M-cycle IEC cooling (MC-DAC) system. The system was compared with a typical conventional solid desiccant evaporative cooling (DAC) system.…”
Section: Integrated With M-cycle Iecmentioning
confidence: 99%
“…Kashif Shahzad et al. 18 analyzed a solid desiccant integrated cross flow M-cycle cooling system. The ambient temperature ranged from 25 °C to 45 °C, and humidity ratio from 12 g kg −1 d.a.…”
Section: Literature Surveymentioning
confidence: 99%