2005
DOI: 10.1109/tasc.2005.849263
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Evaluation of Loss Generation in HTS Coils Under Various Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…For the charging process, B 0 was slightly smaller than a calculated magnetic field B cal (the dashed-dotted line) as indicated by arrow-a. This was caused by a screening current [29][30][31] induced in the Bi-2223 conductor. For I Bi =30 A in the charging process, B 0 was 31.8 mT which is 96.4% of B cal .…”
Section: Behavior Of the Central Magnetic Fieldmentioning
confidence: 99%
“…For the charging process, B 0 was slightly smaller than a calculated magnetic field B cal (the dashed-dotted line) as indicated by arrow-a. This was caused by a screening current [29][30][31] induced in the Bi-2223 conductor. For I Bi =30 A in the charging process, B 0 was 31.8 mT which is 96.4% of B cal .…”
Section: Behavior Of the Central Magnetic Fieldmentioning
confidence: 99%
“…1). The logarithmic decay of the shielding currents is supposed to play the key role to affect the transport current in place of the coupling currents in the LTS wires [5], [6]. However, the current decay behavior of HTS coils has been evaluated only by the joint resistance and E-J characteristics of the HTS tapes, so far, on the other hand, the effect of shielding currents on the current decay behavior of the HTS coils has been discussed in [7].…”
Section: Improvements Of Current Decay Behavior Of Hts Coils In Persimentioning
confidence: 99%
“…The details of the present experiment are discussed in [11] and one of its highlights is briefly introduced in the following. In the present experiment, the magnetic field above the sample coil was measured using a Hall probe and the change of magnetization of the sample coil was monitored.…”
Section: Investigation Of the Mechanism Of Additional Loss Generatmentioning
confidence: 99%
“…This observation indicates that the decaying process of the shielding current is mitigated due to the increase of the critical current density in the HTS tape. Further analysis for the experimental results is given in [11].…”
Section: Investigation Of the Mechanism Of Additional Loss Generatmentioning
confidence: 99%