2021
DOI: 10.1016/j.tsep.2020.100791
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation into the integration of solid desiccant packed beds with oscillating heat pipes for energy efficient isothermal adsorption processes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 37 publications
0
3
0
Order By: Relevance
“…The maximum dehumidification efficiency was 73.9%, increased by 43.8%, and the increase rate was 145.51%. Yeboah et al [30] combined the helically coiled oscillating heat pipes (HCOHPs) using ethanol, methanol and deionized water as working fluids with the packed bed, as shown in Figure 2d. HCOHPs was used to eliminate the heat released by the desiccant adsorbed water vapor, thus reducing the temperature of the packed bed and improving the adsorption performance of the desiccant.…”
Section: Single Materials Packed Bedmentioning
confidence: 99%
See 1 more Smart Citation
“…The maximum dehumidification efficiency was 73.9%, increased by 43.8%, and the increase rate was 145.51%. Yeboah et al [30] combined the helically coiled oscillating heat pipes (HCOHPs) using ethanol, methanol and deionized water as working fluids with the packed bed, as shown in Figure 2d. HCOHPs was used to eliminate the heat released by the desiccant adsorbed water vapor, thus reducing the temperature of the packed bed and improving the adsorption performance of the desiccant.…”
Section: Single Materials Packed Bedmentioning
confidence: 99%
“…Figure 2: (a) Intercooling packed bed[17], (b) Cooling packed bed[28], (c) Internal cooling solid desiccant bed[29], (d) Schematic of the three HCOHPs integrated with the packed bed[30], (e) Schematic diagram of air dehumidification system[31], (f) Structure diagram of fixed bed with water pipes[32].…”
mentioning
confidence: 99%
“…The stability of nano-fluids is a major problem of PHP applications [172]; (4) The current research on PHP work fluids mainly focuses on the heat transfer performance or flow of PHP with a certain work medium [173]. The current research is lacking the selection criteria of the work medium under different conditions, which can only passively test the characteristics of the work fluid in experiments [174].…”
Section: Pressure Fluctuations Of the Phpmentioning
confidence: 99%