Abstract:In this paper we present the results of the ion mobility measurements made in pure isobutane (iC 4 H 10 ) and in mixtures with argon (Ar-iC 4 H 10 ) for a total pressure of 8 Torr (10.6 mbar) and for low reduced electric fields in the 10 Td to 45 Td range (2.4-10.8 kV•cm −1 •bar −1 ), at room temperature. The reduced mobilities, obtained from the peak centroid of the time-of-arrival spectra, are presented for Ar concentrations in the 5%-95% range.
K: Charge transport and multiplication in gas; Gaseous detector… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.