2017
DOI: 10.1107/s2052252517003591
|View full text |Cite|
|
Sign up to set email alerts
|

Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses

Abstract: This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of $40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
86
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 74 publications
(90 citation statements)
references
References 47 publications
3
86
1
Order By: Relevance
“…1b) by measuring the size of particles that are formed when injecting sucrose solution 19 . Sizes were measured by Rayleigh scattering microscopy (RSM) 8 and, in addition, by XFEL diffraction 5,12 . The droplets generated with the GDVN span a wide range of diameters (500 to 2000 nm) whereas droplets generated with the ES aerosoliser are smaller, and more monodisperse (100 to 200 nm).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…1b) by measuring the size of particles that are formed when injecting sucrose solution 19 . Sizes were measured by Rayleigh scattering microscopy (RSM) 8 and, in addition, by XFEL diffraction 5,12 . The droplets generated with the GDVN span a wide range of diameters (500 to 2000 nm) whereas droplets generated with the ES aerosoliser are smaller, and more monodisperse (100 to 200 nm).…”
Section: Resultsmentioning
confidence: 99%
“…The sizes of injected sucrose, carboxysome and TBSV particles were determined by fitting the diffraction image of a uniform sphere model to the measured diffraction patterns 12 . Table 2 lists the data sets that were used.…”
Section: Particle Size Determination From Xfel Diffraction Intensitiesmentioning
confidence: 99%
See 1 more Smart Citation
“…"Open science, data sharing, software sharing is the future of science", Carly Strasser says [209]. For SPI, this concept has also been accepted and will be extended to a wider range [217][218][219][220]. At the moment, most published data has been uploaded to the Coherent X-ray Imaging Data Bank (CXIDB) [221,222].…”
Section: Summary and Future Prospectsmentioning
confidence: 99%
“…This scheme of 'diffraction-before-destruction' is routinely used for Serial Femtosecond Crystallography a klaus.giewekemeyer@xfel.eu b present address: SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park (CA) 94025, USA c present address: Deutsches Elektronen-Synchrotron, Notkestrae 85, 22607 Hamburg, Germany d present address: NSLS-II, Brookhaven National Laboratory, P.O. Box 5000, Upton (NY) 11973, USA [3,4] and has been demonstrated for single biological particles as small as 45 nm in diameter [5].…”
Section: Introductionmentioning
confidence: 99%