2015
DOI: 10.1007/s10518-015-9748-8
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on behavior of anchored external shear wall panel connections

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…This provided an interlocking mechanism that enabled the grout to effectively bond with the spliced bars. Meanwhile, Solak [50] employed epoxy to anchor the connections. According to the results, the ductility of the specimens with the connections was significantly lower than the monolithic specimens.…”
Section: Wall-panel Connectionsmentioning
confidence: 99%
“…This provided an interlocking mechanism that enabled the grout to effectively bond with the spliced bars. Meanwhile, Solak [50] employed epoxy to anchor the connections. According to the results, the ductility of the specimens with the connections was significantly lower than the monolithic specimens.…”
Section: Wall-panel Connectionsmentioning
confidence: 99%
“…There are three methods of assembling the AHW connections in the PCSW structures: (a) splicing longitudinal rebars using sleeves or stirrups combined with high-strength mortar [7][8][9]; (b) tying together the horizontal connections using unbounded posttensioned (UPT) precast concrete wall plates [2,10,11]; (c) connecting the longitudinal rebars using bolted connections [12,13]. Several studies [1,8,11] indicate that the required mechanical properties of the AHW connections can be achieved with the assembly connection methods mentioned above by adopting effective construction measures.…”
Section: Horizontal Connectionmentioning
confidence: 99%
“…where l p is the equivalent plastic hinge region height which can be defined as l p � (0.20 + 0.044H/h w )h w , where h w is the cross section length. e formula of l p is generally a good estimate for RC shear walls [9].…”
Section: Calculation Of δ Y1 δ U1mentioning
confidence: 99%
“…What is more, the implementing subjects continue rise, for example, the prefabricated concrete shear wall structure system of Zhongnan Group [8]. For the prefabricated shear wall structure, the horizontal connection in the structure is the key to ensure structural integrity and seismic performance [9], and for this purpose, the authors invent a new horizontal connection [10] whose bearing capacity has been studied; however, the ductility which unbonded reinforcement can improve has not been studied.…”
Section: Introductionmentioning
confidence: 99%