Experimental Study on the Feasibility of Quick Startup of Instant Heat Pump Water Heaters Based on Active Control of Heat Sink Flow Step

Fujun Ju,
Zhenzhen Mu,
Guozhu Li
et al.

Abstract: The influence of flow step ratio (FSR) on the startup characteristics of instant heat pump water heaters (IHPWHs) with natural mixture M (R744/R290 (12/88)) under nominal conditions was studied experimentally to verify the feasibility of a new quick startup method. The results show that the FSR had a marked effect on the startup time of system performance parameters. Under the optimal FSR of 0.6, the shortest system startup time and available hot water supply time were 700 s and 250 s, respectively, which were… Show more