Experimental validation of a framework for hygro-mechanical simulation of self-induced stresses in concrete

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
17
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
3

Relationship

3
4

Authors

Journals

citations
Cited by 22 publications
(17 citation statements)
references
References 19 publications
0
17
0
Order By: Relevance
“…In that experimental campaign, shrinkage was also measured in 2 mm thick cement paste specimens, exposed to variable relative humidity values. Given than this drying shrinkage model provided a good agreement with the experimental results for specimens of the three thicknesses -see Azenha et al (2017) -it is expected to provide an acceptable estimated for the 50 cm thick member, bearing in mind the objectives of the present work. It should be noted that the concrete material properties considered for the structures analysed in this paper correspond to the ones of the experimental campaign described in Azenha et al (2017).…”
mentioning
confidence: 66%
See 3 more Smart Citations
“…In that experimental campaign, shrinkage was also measured in 2 mm thick cement paste specimens, exposed to variable relative humidity values. Given than this drying shrinkage model provided a good agreement with the experimental results for specimens of the three thicknesses -see Azenha et al (2017) -it is expected to provide an acceptable estimated for the 50 cm thick member, bearing in mind the objectives of the present work. It should be noted that the concrete material properties considered for the structures analysed in this paper correspond to the ones of the experimental campaign described in Azenha et al (2017).…”
mentioning
confidence: 66%
“…where t is the time and * H D is the diffusion parameter which lumps the diffusivity and the moisture capacity of the material. The validity of this modelling approach was justified by Azenha et al (2017). * H D is given by the following equation, initially proposed by Bazant and Najjar (1972):…”
Section: Hygral Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…This is usually referred to as the ‘self‐restraining’ effect and can cause surface cracks and curling/buckling of floors. It should be noted that this effect occurs in both restrained and free elements and the corresponding surface cracks may reduce in width after moisture equilibrium between the element and the environment 17–19 . When studying drying shrinkage, samples are generally rather small/thin, at least in one direction, either plate‐like or small beams.…”
Section: Significance Of Restraining Devices For Time‐dependent Behavmentioning
confidence: 99%