2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) 2013
DOI: 10.1109/apec.2013.6520512
|View full text |Cite
|
Sign up to set email alerts
|

Experimental validation of a parallel hybrid modular multilevel voltage source converter for HVDC transmission

Abstract: This paper discusses a small scale laboratory model constructed to validate the operation of a recently proposed parallel hybrid modular multilevel voltage source converter which is intended for HVDC applications. The converter is characterized by a 'chainlink' arrangement composed of a number of half bridge cells capable of operating with bidirectional current and an associated full bridge converter for each converter phase arrangement. Each half bridge cell is made up of two bidirectional switches and a loca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 31 publications
(12 citation statements)
references
References 4 publications
0
12
0
Order By: Relevance
“…The model is implemented using PLECS. The power flow control between the power converter and the grid, the power balance between the power converter and the DC circuit and the cell voltage control are achieved with the control schemes discussed in [7,9,10,17]. …”
Section: Modelling and Simulationmentioning
confidence: 99%
See 2 more Smart Citations
“…The model is implemented using PLECS. The power flow control between the power converter and the grid, the power balance between the power converter and the DC circuit and the cell voltage control are achieved with the control schemes discussed in [7,9,10,17]. …”
Section: Modelling and Simulationmentioning
confidence: 99%
“…In [7,10,13], the use of triplen harmonics are explored for modulation ratio control in the parallel hybrid modular multilevel converter (PH-M2L-VSC) allowing PQ control and DC link voltage ripple reduction. In these papers, the studies considered a balanced symmetrical grid with equal amount of triplen harmonic injected in each chain-link to allow fundamental frequency ac converter voltage control.…”
Section: Proposed Control Concept For Sustained Operation During Gridmentioning
confidence: 99%
See 1 more Smart Citation
“…Research into the performance of the converter in a balanced network is presented in [7,[26][27][28][29][30]. The authors of [31] investigated the operation of the converter with a depressed AC voltage by introducing voltage notches in the AC voltages which has an effect on the DC bus voltage similar to the staggered voltage operation of the converter chainlinks in [5].…”
Section: Introductionmentioning
confidence: 99%
“…Recently, hybrid voltage source converters such as the parallel hybrid VSC [5,17] and the Alternate Arm Converter (AAC) [6,18], combining features of two-level and modular multi-Level converters have been proposed to achieve high waveform fidelity, lower loss and/or DC fault blocking capability.…”
Section: Introductionmentioning
confidence: 99%