Abstract:Background: Multiaxial dynamic loadings occur in many industrial cases and multiaxial dynamic test development is thus a crucial issue. Objective: To meet this challenge, a biaxial compression Hopkinson bar set-up is designed. Methods: The set-up consists of a striker, an input bar, an internal output bar and a co-axial external output tube (surrounding the internal bar). The internal output bar measures the axial loading of the cross sample whereas the external output bar measures the transverse one via a mec… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.