2008
DOI: 10.1016/j.ophtha.2008.01.007
|View full text |Cite
|
Sign up to set email alerts
|

Exploring the Heidelberg Retinal Tomograph 3 Diagnostic Accuracy across Disc Sizes and Glaucoma Stages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
24
1
11

Year Published

2009
2009
2019
2019

Publication Types

Select...
6
2
1

Relationship

3
6

Authors

Journals

citations
Cited by 42 publications
(38 citation statements)
references
References 21 publications
2
24
1
11
Order By: Relevance
“…31,32 Unlike previous studies that largely analyzed sensitivities and specificities only, our study evaluated PPV and NPV performance indices, as PPV and NPV are influenced strongly by disease prevalence. 30 This analysis indicated that the ISNT rule and its variants, determined based on the HRT, have limited value in population-based detection of glaucoma.…”
Section: Discussionmentioning
confidence: 99%
“…31,32 Unlike previous studies that largely analyzed sensitivities and specificities only, our study evaluated PPV and NPV performance indices, as PPV and NPV are influenced strongly by disease prevalence. 30 This analysis indicated that the ISNT rule and its variants, determined based on the HRT, have limited value in population-based detection of glaucoma.…”
Section: Discussionmentioning
confidence: 99%
“…The sensitivity of CSM was estimated to be 86% for a fixed specificity of 90% corresponding to a cutoff value of Ϫ0. 15. Complete details are given in Table 4 (available online at http://aaojournal.org).…”
Section: Continuous Parametersmentioning
confidence: 99%
“…[2][3][4][5][6][7][8] The commer-cially available CSLO, the Heidelberg Retinal Tomograph (HRT; Heidelberg Engineering GmbH, Dossenheim, Germany) is the leading device for a 3-dimensional quantitative study and classification of the ONH shape. 9 -14 Despite its good overall diagnostic performance, the accuracy of the discrimination between normality and glaucoma has been shown to be significantly influenced by ONH shape and size; specifically, it has been shown that larger optic discs are associated with lower specificities and smaller discs with lower sensitivities, [15][16][17][18][19][20] thus limiting the role of quantitative ONH assessment in the clinical diagnostic process.…”
mentioning
confidence: 99%
“…Numerous studies [5][6][7][8][9]26 have been performed to determine the best HRT parameters for discriminating between healthy and glaucoma subjects. Others studies [18][19][20]27 have focused on developing discriminant functions to improve the diagnostic ability of HRT parameters.…”
Section: Discussionmentioning
confidence: 99%