2021
DOI: 10.1021/acs.analchem.0c04341
|View full text |Cite
|
Sign up to set email alerts
|

Exploring the Impacts of Conformer Selection Methods on Ion Mobility Collision Cross Section Predictions

Abstract: The prediction of structure dependent molecular properties, such as collision cross sections as measured using ion mobility spectrometry, are crucially dependent on the selection of the correct population of molecular conformers. Here, we report an in-depth evaluation of multiple conformation selection techniques, including simple averaging, Boltzmann weighting, lowest energy selection, low energy threshold reductions, and similarity reduction. Generating 50 000 conformers each for 18 molecules, we used the In… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 55 publications
0
8
0
Order By: Relevance
“…Finding the two most dissimilar conformers is trivial, but finding the subsets of three or more is not. As part of a larger analysis to assess the validity of various conformer selection techniques [ 6 ], a method was needed to efficiently find the subset of the n most dissimilar molecular conformers out of a set of 50,000 conformers (where 1 < n < 50,000). These conformers were generated by a modified ISiCLE pipeline on a set of 18 small molecules with mass ranges of ~100–700 Da, as described previously [ 6 ].…”
Section: Application: Molecular Conformer Samplingmentioning
confidence: 99%
See 2 more Smart Citations
“…Finding the two most dissimilar conformers is trivial, but finding the subsets of three or more is not. As part of a larger analysis to assess the validity of various conformer selection techniques [ 6 ], a method was needed to efficiently find the subset of the n most dissimilar molecular conformers out of a set of 50,000 conformers (where 1 < n < 50,000). These conformers were generated by a modified ISiCLE pipeline on a set of 18 small molecules with mass ranges of ~100–700 Da, as described previously [ 6 ].…”
Section: Application: Molecular Conformer Samplingmentioning
confidence: 99%
“…A nontrivial problem is creating sets of conformers and selecting the critical few that should be used for the final property calculations. Thus, several groups have striven to create algorithms and automated pipelines in order to smartly sample conformers sets: e.g., clustering methods [ 1 ], randomly sampling (with or without simulated annealing) [ 2 , 3 , 4 ], or selecting low energy sets from classical or semiempirical molecular modeling [ 5 , 6 ]. Part of the goal of downselecting to a smaller set of conformers is to save on the relatively high computational cost when performing quantum chemical calculations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…One possible explanation for the discrepancy with fentanyl could be that the structure was trapped in a local energy minimum. A way to mitigate this issue is by having more robust conformer sampling, such as generating or testing more structures or by differing the sampling methods . When optimizing the protonated fentanyl conformer structure provided in Lau et al at the same level of theory as the other molecules in Table , the LE BD was 1.630 Å, which is indicative of internal bridging and is more in line with the other bond distances (see Table , fentanyl*).…”
Section: Resultsmentioning
confidence: 98%
“…Proton affinity and gas-phase basicity values were generated according to eqs 4 and 5 for all amines and amides adducts described in the Validation Library Section. The calculated values for all conformers of a protonated isomer population are Boltzmann weighted 39 according to total energies, yielding one PA and GB for each ion location.…”
Section: ■ Introductionmentioning
confidence: 99%