2023
DOI: 10.1016/j.xphs.2022.10.012
|View full text |Cite
|
Sign up to set email alerts
|

Extensive Characterization of Polysorbate 80 Oxidative Degradation Under Stainless Steel Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
20
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 13 publications
(21 citation statements)
references
References 32 publications
1
20
0
Order By: Relevance
“…The main methods used to identify the degradation products in other studies are a full scan [7][8][9][10][11][12] or charged aerosol detection. [13][14][15][16] Since the data obtained by charged aerosol detection do not include mass information, distinguishing PS80 degradation products with different esterified FAs is impossible. In addition, in a full scan, the detection of low-concentration oxidative degradation products is usually difficult because the signals of these products may be obscured by those of components present at high concentrations within the same retention time.…”
Section: Composition Ratio Of Oxidative Degradation Products and Chan...mentioning
confidence: 99%
See 3 more Smart Citations
“…The main methods used to identify the degradation products in other studies are a full scan [7][8][9][10][11][12] or charged aerosol detection. [13][14][15][16] Since the data obtained by charged aerosol detection do not include mass information, distinguishing PS80 degradation products with different esterified FAs is impossible. In addition, in a full scan, the detection of low-concentration oxidative degradation products is usually difficult because the signals of these products may be obscured by those of components present at high concentrations within the same retention time.…”
Section: Composition Ratio Of Oxidative Degradation Products and Chan...mentioning
confidence: 99%
“…However, commercially available polysorbate products contain substantial amounts of byproducts, and various analytical methods have been developed for their detection. [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23] PS80 is known to be oxidatively or enzymatically degraded, and the degradation of PS80 can sometimes affect protein stability. 3,7,8,[24][25][26] Therefore, polysorbate degradation has emerged as a major challenge in the biopharmaceutical community.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…PS-80 was spiked in Protein A purified samples to compare lipase activities. Previous reports indicate PS-80 degradation rates are elevated at higher temperature (Zheng et al, 2023); thus, these samples were held at 40°C for 14 days. The results of the PS-80 (14 days at 40°C) after full downstream purification steps (with the second polishing chromatography).…”
Section: Ps-80 Stability Of the Purified Samplesmentioning
confidence: 99%