2017
DOI: 10.1111/cid.12495
|View full text |Cite
|
Sign up to set email alerts
|

Extra oral digital scanning and imaging superimposition for volume analysis of bone remodeling after tooth extraction with and without 2 types of particulate porcine mineral insertion: A randomized controlled trial

Abstract: At the 4-month analysis both test groups showed reduced bone loss when compared to naturally healing sockets. However, the 2 grafting materials were not able to preserve the alveolar crest, and a reduction close to 30% in the estimates was registered after healing.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
31
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 21 publications
(34 citation statements)
references
References 25 publications
2
31
1
Order By: Relevance
“…Both studies used cancellous porcine xenografts that were processed from the same tissue processor, and ridge preserved sites were allowed approximately the same amount of healing time. The difference between the two studies is that Guarnieri et al . included premolar‐ molar sites and used a resorbable collagen membrane over the graft material, whereas the current study used a d‐PTFE membrane and only included anterior and premolar sites.…”
Section: Discussionmentioning
confidence: 97%
“…Both studies used cancellous porcine xenografts that were processed from the same tissue processor, and ridge preserved sites were allowed approximately the same amount of healing time. The difference between the two studies is that Guarnieri et al . included premolar‐ molar sites and used a resorbable collagen membrane over the graft material, whereas the current study used a d‐PTFE membrane and only included anterior and premolar sites.…”
Section: Discussionmentioning
confidence: 97%
“…As regards the advantages seen from our study, we can cite that the present technique is a noninvasive procedure for patients, as a 3‐dimensional optical scanner is employed without any source of X‐ray radiation for the volumetric survey; moreover, data acquisition appears acceptable for patients and easy for the clinician, consisting of an impression being made of the arch and the production of a model cast. The semi‐automaticity of further digital steps (voxelization, fusion, and VOI detection) guarantees, as has been proven by previous studies, a high degree of accuracy due to the single file production (from baseline to 4 months' survey), in which the changes in volume and area of treated and untreated sockets can be easily investigated.…”
Section: Discussionmentioning
confidence: 74%
“…The STL files were read by a matrix elaborator (MatLab 7.11, The MathWorks, Natick, Massachusetts). Full‐arch digital models of each patient were voxelized and superimposed by using best‐fit algorithm as described by Barone and colleagues; each file was then saved as dicom images with the following acquisition parameters: ∅FOV 102.4 mm, voxel dimension 0.1 mm.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations