2018
DOI: 10.21577/0103-5053.20180130
|View full text |Cite
|
Sign up to set email alerts
|

Fast Ephedrine Quantification by Gas Chromatography Mass Spectrometry

Abstract: Ephedrines are widely used in therapy. Because of their stimulant properties, these substances are relevant in different forensic fields. At present, the state of the art for ephedrines quantification relay based on a liquid chromatography mass spectrometry, mainly because of the dilute-andshoot approach. Notwithstanding, several gas chromatography based methods have already been described, all of them include cleanup steps, with the potential disadvantage of incurring errors and increasing the workload. In th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…The injector, column and mass spectrometry conditions were the same as described by Carneiro et al 21 The GC temperature programming was set as follows: initial column oven temperature 130°C (held 1 minute), then programmed to increase to 210°C at 10°C/min, then to 250°C at 10°C/min and to 300°C at 30°C/min. The injector, column and mass spectrometry conditions were the same as described by Carneiro et al 21 The GC temperature programming was set as follows: initial column oven temperature 130°C (held 1 minute), then programmed to increase to 210°C at 10°C/min, then to 250°C at 10°C/min and to 300°C at 30°C/min.…”
Section: Gc-ms Conditionsmentioning
confidence: 99%
See 4 more Smart Citations
“…The injector, column and mass spectrometry conditions were the same as described by Carneiro et al 21 The GC temperature programming was set as follows: initial column oven temperature 130°C (held 1 minute), then programmed to increase to 210°C at 10°C/min, then to 250°C at 10°C/min and to 300°C at 30°C/min. The injector, column and mass spectrometry conditions were the same as described by Carneiro et al 21 The GC temperature programming was set as follows: initial column oven temperature 130°C (held 1 minute), then programmed to increase to 210°C at 10°C/min, then to 250°C at 10°C/min and to 300°C at 30°C/min.…”
Section: Gc-ms Conditionsmentioning
confidence: 99%
“…21 The number of fish was the principal variable for investigation because it is directly related to the kinetics of the process, and the concentration of the drug in the ZWT was evaluated because it is a relevant variable for other in vivo models. 21 The number of fish was the principal variable for investigation because it is directly related to the kinetics of the process, and the concentration of the drug in the ZWT was evaluated because it is a relevant variable for other in vivo models.…”
Section: Optimization Of the Zwt Model For Sib Metabolismmentioning
confidence: 99%
See 3 more Smart Citations