2012
DOI: 10.1007/s12161-012-9528-x
|View full text |Cite
|
Sign up to set email alerts
|

Fast Sequential Determination of As and Sb, Bi and Pb by Continuous Flow Hydride Generation Atomic Absorption Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…In order to quantify antimony in the concentration level established by the various legislations, the analytical technique should have a low limit of quantification and good precision and accuracy. The analytical techniques most commonly employed to determine antimony in polymers and in beverages are graphite furnace atomic absorption spectrometry (GFAAS), fast sequential flame atomic absorption spectrometer (FS-FAAS), inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS) with or without hydride generation, and X-ray fluorescence (XRF) (Cadore et al 2008;Guerra et al 2011;Shimamoto et al 2011;Batista et al 2013;Jesus et al 2016;Altunay et al 2016).…”
Section: Introductionmentioning
confidence: 99%
“…In order to quantify antimony in the concentration level established by the various legislations, the analytical technique should have a low limit of quantification and good precision and accuracy. The analytical techniques most commonly employed to determine antimony in polymers and in beverages are graphite furnace atomic absorption spectrometry (GFAAS), fast sequential flame atomic absorption spectrometer (FS-FAAS), inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS) with or without hydride generation, and X-ray fluorescence (XRF) (Cadore et al 2008;Guerra et al 2011;Shimamoto et al 2011;Batista et al 2013;Jesus et al 2016;Altunay et al 2016).…”
Section: Introductionmentioning
confidence: 99%
“…The system of CF-HG-AAS employed in this work was previously optimized. 19 It was composed by 8 channels peristaltic pump (MCP model; Ismatec, Wertheim, Germany), Tygon  propulsion tubes (Saint-Gobain, Courbevoie, France) with different diameters, a gas-liquid separator. A mass flow controller (ASA Srl, Sesto San Giovanni, MI, Italy) was utilized to control the carrier gas argon flow rate (White Martins, São Paulo, SP, Brazil).…”
Section: Instrumentationmentioning
confidence: 99%
“…28 According to the study, lead poisoning was also responsible for 230,000 premature deaths in India. In light of these concerns, there has been a growing effort to develop innovative strategies for lead ion detection These approaches include conventional methods such as inductively coupled plasma mass spectrometry (ICP-MS), 29,30 atomic absorption spectrometry (AAS), 31,32 atomic emission spectrometry (AES), 33,34 stripping voltammetry (SV), 35,36 and other emerging methods such as colorimetric-, fluorimetric-, and aptamer-based sensors. 37−42 Among these methods, colorimetric methods have garnered substantial interest due to their cost-effectiveness and ease of naked-eye detection, while fluorimetric sensors have been highly regarded for their superior sensitivity and dependable performance.…”
Section: Introductionmentioning
confidence: 99%
“…These approaches include conventional methods such as inductively coupled plasma mass spectrometry (ICP-MS), , atomic absorption spectrometry (AAS), , atomic emission spectrometry (AES), , stripping voltammetry (SV), , and other emerging methods such as colorimetric-, fluorimetric-, and aptamer-based sensors. Among these methods, colorimetric methods have garnered substantial interest due to their cost-effectiveness and ease of naked-eye detection, while fluorimetric sensors have been highly regarded for their superior sensitivity and dependable performance. Dual-output colorimetric and fluorimetric sensors provide the benefit of both easy visual detection and enhanced sensitivity opening a scope for on-field applications …”
Section: Introductionmentioning
confidence: 99%