2017
DOI: 10.1016/j.snb.2016.09.035
|View full text |Cite
|
Sign up to set email alerts
|

Fast simultaneous detection of three pesticides by a White Light Reflectance Spectroscopy sensing platform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 35 publications
(18 citation statements)
references
References 42 publications
0
18
0
Order By: Relevance
“…Limit of detection (LOD) in ppm HPLC-MS 0.014 [6] HPLC/GC-MS 0.01-0.05 [15] HPLC-UV detector 0.01 [5] ELISA 0.110-3 [19] Capillary electrophoresis 0.1-1 [81] White light reflectance spectroscopy 0.06 [82] Chemi-impedimetric sensor 0.0016-0.0042 (this work)…”
Section: Methodsmentioning
confidence: 99%
“…Limit of detection (LOD) in ppm HPLC-MS 0.014 [6] HPLC/GC-MS 0.01-0.05 [15] HPLC-UV detector 0.01 [5] ELISA 0.110-3 [19] Capillary electrophoresis 0.1-1 [81] White light reflectance spectroscopy 0.06 [82] Chemi-impedimetric sensor 0.0016-0.0042 (this work)…”
Section: Methodsmentioning
confidence: 99%
“…In Figure 7a, the CRP calibration curves obtained using chips modified with 2% The stability of the anti-CRP antibodies immobilized onto chips modified with APTES following different protocols was also tested through the performance of repeated cycles of immunoreactions and surface regeneration, that is, removal of immune complexes formed during the assay. For surface regeneration, a 0.1 M glycine-HCl buffer, pH 2.5, was used, which has been determined as optimal for this particular antibody in previous publications (Koukouvinos et al, 2018;Koukouvinos, Metheniti, et al, 2017;Koukouvinos, Τsialla, et al, 2017). The results obtained from chips modified with 2% ( F I G U R E 7 (a) Typical CRP calibration curves obtained from chips modified with 2% (v/v) APTES in water (black squares), 5% (v/v) APTES in ethanol (red squares) and 5% (v/v) APTES in ethanol and glutaraldehyde (blue squares).…”
Section: Development Of Wlrs Sensor For the Immunochemical Determinmentioning
confidence: 99%
“…For the label-free and real-time detection of chlorpyrifos in water and wine samples, Koukouvinos et al [107] developed a biosensor based on white light reflectance spectroscopy (WLRS) (Figure 4a) and a competitive immunoassay format (Figure 4b). The LOD was 0.6 ng/mL with an analysis time of about 10 min.…”
Section: Immunosensors For Pesticide Determinationmentioning
confidence: 99%