2011
DOI: 10.1016/j.joen.2011.03.023
|View full text |Cite
|
Sign up to set email alerts
|

Fatigue Testing of Controlled Memory Wire Nickel-Titanium Rotary Instruments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

9
168
2
12

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 161 publications
(191 citation statements)
references
References 25 publications
9
168
2
12
Order By: Relevance
“…The ProGlider file used in this study is manufactured from M-wire NiTi alloy while G-Files are made from conventional NiTi. Heat-treated M-wire alloy has a control memory feature that makes this alloy extremely flexible and more resistant to cyclic fatigue than non-control memory NiTi alloy (32). The performance of G-Files at Dmc in the present study may also be due to the constant 3% taper or the noncutting tips.…”
Section: Resultsmentioning
confidence: 73%
“…The ProGlider file used in this study is manufactured from M-wire NiTi alloy while G-Files are made from conventional NiTi. Heat-treated M-wire alloy has a control memory feature that makes this alloy extremely flexible and more resistant to cyclic fatigue than non-control memory NiTi alloy (32). The performance of G-Files at Dmc in the present study may also be due to the constant 3% taper or the noncutting tips.…”
Section: Resultsmentioning
confidence: 73%
“…Reciprocating instrumentation is a new and promising method for the mechanical disinfection of root canals, and as with the M-Wire NiTi alloy, allows the root canal to be prepared with a single instrument. Some studies have evaluated the mechanical effectiveness of these instruments using mechanical tests, 16,17,22,23,24 and have reported the great potential these new concepts have in overcoming the challenges presented during root canal manipulation, such as curvatures. 15,22 However, simplification of endodontic treatment using only one instrument raises concerns about its effectiveness in promoting proper disinfection of the root canal system.…”
Section: Discussionmentioning
confidence: 99%
“…CM Wire instruments had a higher number of multiple-crack origins than conventional NiTi wire files of the same design, especially NEYY CM instruments (92% files with multiple-crack origins). Nearly all of the specimens showed fatigue crack initiation at 1 or more cutting edges of the fracture crosssection unless a subsurface void or inclusion was present elsewhere (39). The values of the fracture area occupied by the dimple region (showing the final fracture) were significantly smaller on NiTi instruments made from CM Wire than on instruments made from conventional NiTi wire ( Fig.…”
Section: Wirementioning
confidence: 92%
“…The explanation for this may be that heating transforms the metal temporarily into the austenitic phase and makes it SE, which makes it possible for the file to regain its original shape before cooling down again. The properties of the bulk materials are the main determinant of fatigue life (35)(36)(37)(38)(39)(40)(41)(42) (42)(43)(44)(45). The conventional SE NiTi file has an austenite structure (26,(42)(43)(44)(45)(46), whereas NiTi file with thermal processing (eg, TYP CM and Vortex) would essentially be in the martensite condition at body temperature (42,44,45,47).…”
Section: Metallurgical Characterization Of Thermomechanically-treatedmentioning
confidence: 99%
See 1 more Smart Citation