IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society 2012
DOI: 10.1109/iecon.2012.6389150
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of EMG-based ANN controller for a real-time virtual reality simulation

Abstract: Estimation of the joint angle from the surface electromyography (sEMG) is a quite complex task due to the complicated relationship between the kinematical variables and the raw sEMG. In this paper, we build a sEMG-to-motion model with the artificial neural network (ANN). EMG features, including Integral of absolute value (IA V), Zero crossing (ZC), Auto-regression coefficients (ARC), Median frequency (MDF), are extracted as the input of the ANN, and the output of the ANN is the operator's elbow joint angle and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…For stroke survivors at BS IV or above, although the synergy pattern still exists, due to the significant increment of their muscle strength and endurance in most cases, a better muscle control enables them to finish the movements at a higher standard with some consistency [ 26 ]. Stroke survivors at BS VI are very rare in hospitals, and they can perform ADLs almost the same as healthy people [ 27 ]. To some extent, the participation of healthy subjects acts as that of stroke survivors at BS VI.…”
Section: Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For stroke survivors at BS IV or above, although the synergy pattern still exists, due to the significant increment of their muscle strength and endurance in most cases, a better muscle control enables them to finish the movements at a higher standard with some consistency [ 26 ]. Stroke survivors at BS VI are very rare in hospitals, and they can perform ADLs almost the same as healthy people [ 27 ]. To some extent, the participation of healthy subjects acts as that of stroke survivors at BS VI.…”
Section: Materials and Methodsmentioning
confidence: 99%
“…The data collected from accelerometers and gyroscopes were low-pass filtered with a fourth-order Butterworth filter (cut-off frequency: 5 Hz), while the sEMG signal was band-pass filtered with a fourth-order Butterworth filter (cut-off frequency: 10–500 Hz) to eliminate the surrounding noise [ 27 ]. The Z-score normalization method was used for signals of each activity.…”
Section: Materials and Methodsmentioning
confidence: 99%