2014
DOI: 10.4236/ijmpcero.2014.32016
|View full text |Cite
|
Sign up to set email alerts
|

Feasible Method to Assess the Performance of a Lung Cancer CT Screening CAD System in Clinical Practice: Dependence on Nodule Size and Density

Abstract: Detection of small pulmonary nodules is the goal of lung cancer screening. Computer-aided detection (CAD) systems are recommended to use in lung cancer computed tomography (CT) screening to increase the accuracy of nodule detection. Size and density of lung nodules are primary factors in determining the risk of malignancy. Therefore, purpose of this study is to apply computer-simulated virtual nodules based on the point spread function (PSF) measured in same scanner (maintaining spatial resolution condition) t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2017
2017
2017
2017

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(7 citation statements)
references
References 35 publications
0
7
0
Order By: Relevance
“…We have explored the feasibility of using this method to assess CAD performance; in this study, the virtual nodules were suggested to be useful for generating free-response receiver-operating characteristic curves for a CAD system. 16 However, in this preliminary study, the validity of the use of virtual nodules as an alternative to artificial nodules included in a lung phantom was not verified. A comparative study between virtual and artificial nodules is necessary.…”
Section: Introductionmentioning
confidence: 71%
See 1 more Smart Citation
“…We have explored the feasibility of using this method to assess CAD performance; in this study, the virtual nodules were suggested to be useful for generating free-response receiver-operating characteristic curves for a CAD system. 16 However, in this preliminary study, the validity of the use of virtual nodules as an alternative to artificial nodules included in a lung phantom was not verified. A comparative study between virtual and artificial nodules is necessary.…”
Section: Introductionmentioning
confidence: 71%
“…In this study, we first validated the application of virtual nodules [13][14][15][16] regarding their use for the evaluation of CAD performance in place of artificial nodules included in a lung phantom. Next, as a further validation study, virtual nodules were made to appear to be comparable with real nodules with regard to size and density and were applied to the detection test of the CAD system.…”
Section: Introductionmentioning
confidence: 99%
“…This method potentially overcomes the limitations of previous simulation techniques for pulmonary nodules. [4][5][6][7][8][9][10][11][13][14][15][16][17][18]21 Our proposed method includes direct deconvolution by division of spatial frequencies. This analysis is essentially the same as a common image deblurring (or restoration).…”
Section: Discussionmentioning
confidence: 99%
“…The authors have explored and developed another approach to the computer generation of virtual nodules . In this method, virtual nodules are computed from object functions based on the spatial resolution characteristics measured for each CT system .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation