2017
DOI: 10.1002/jor.23785
|View full text |Cite
|
Sign up to set email alerts
|

Femoral version: Comparison among advanced imaging methods

Abstract: In choosing a modality to determine femoral version, consider the advantages and disadvantages of each modality for the individual patient, using femoral neck oblique slices for CT and MRI when available. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1536-1542, 2018.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
27
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 32 publications
(27 citation statements)
references
References 14 publications
(27 reference statements)
0
27
0
Order By: Relevance
“…115,125 Biplanar radiographs with 3D modeling are being increasingly used for torsional assessment and constitute a low-dose alternative to CT with comparable results. 124 The 3D-based measurements were reported to be reproducible and independent of femur positioning, overcoming major reproducibility issues encountered with 2D methods. 126 Various measurement methods are reported in the literature for assessing this angle.…”
Section: Femoral Torsionmentioning
confidence: 99%
See 1 more Smart Citation
“…115,125 Biplanar radiographs with 3D modeling are being increasingly used for torsional assessment and constitute a low-dose alternative to CT with comparable results. 124 The 3D-based measurements were reported to be reproducible and independent of femur positioning, overcoming major reproducibility issues encountered with 2D methods. 126 Various measurement methods are reported in the literature for assessing this angle.…”
Section: Femoral Torsionmentioning
confidence: 99%
“…115,121 Initially, femoral torsion was measured on radiographs, 31 but CT and MRI are currently the preferred modalities to determine this parameter. 124 Although a globally accepted measurement method remains to be ascertained, adequate anatomical measurements of femoral torsion can be performed on CT and MRI systematically using strict axial slices. 115,125 Biplanar radiographs with 3D modeling are being increasingly used for torsional assessment and constitute a low-dose alternative to CT with comparable results.…”
Section: Femoral Torsionmentioning
confidence: 99%
“…The magnetic resonance imagingebased version measurements used by Lall et al are acceptable, but the gold standard for measuring version is based on a 3dimensional computed tomography model. 9 Besides, these excellent outcomes from experienced surgeons at a dedicated hip arthroscopy center may not be generalizable to community practice. Despite these shortcomings, this study does prove that patients with femoral retroversion can benefit from comprehensive hip arthroscopic treatment.…”
Section: See Related Article On Page 3035mentioning
confidence: 99%
“…All 3D models were imported into custom MATLAB (Mathworks, Natick, MA, USA) software for femoral torsion and pin angle calculations. Femoral torsion was automatically calculated using a custom a MATLAB program, thus eliminating human measurement error [13]. Femur models were reoriented based on the mechanical axis (MA) and the anatomical axis (AA).…”
Section: Femoral Torsion Measurement Techniquementioning
confidence: 99%