2011
DOI: 10.1103/physrevstab.14.120701
|View full text |Cite
|
Sign up to set email alerts
|

Femtosecond x-ray pulse temporal characterization in free-electron lasers using a transverse deflector

Abstract: We propose a novel method to characterize the temporal duration and shape of femtosecond x-ray pulses in a free-electron laser (FEL) by measuring the time-resolved electron-beam energy loss and energy spread induced by the FEL process, with a transverse radio-frequency deflector located after the undulator. Its merits are simplicity, high resolution, wide diagnostic range, and noninvasive to user operation. When the system is applied to the Linac Coherent Light Source, the world's most powerful x-ray FEL, it c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
67
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 81 publications
(70 citation statements)
references
References 12 publications
0
67
0
Order By: Relevance
“…6 indicates that the beam slice energy spread copies the distribution of FEL power. Therefore, measurement of the time-dependent energy distribution of an electron beam after the undulator sections may allow one to obtain the temporal profile of the x rays [37].…”
Section: Realistic Cases At Lcls and Lcls-iimentioning
confidence: 99%
“…6 indicates that the beam slice energy spread copies the distribution of FEL power. Therefore, measurement of the time-dependent energy distribution of an electron beam after the undulator sections may allow one to obtain the temporal profile of the x rays [37].…”
Section: Realistic Cases At Lcls and Lcls-iimentioning
confidence: 99%
“…25). The slight slippage of the radiation pulse relative to the electron bunch is neglected here, as it is typically a small fraction of the achieved temporal resolution.…”
Section: Article Nature Communications | Doi: 101038/ncomms4762mentioning
confidence: 99%
“…We extended the transverse deflector diagnostic scheme to retrieve the detailed X-ray pulse duration and temporal profile by measuring this lasing footprint 25 . The sketch in Fig.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…In recent years various methods have been proposed and developed for accurate measurements of relative arrival times (Bionta et al, 2011;Tavella et al, 2011;Dü sterer et al, 2011; Ding et al, 2011;Dü sterer et al, 2011;Inubushi et al, 2012;Grguraš et al, 2012;Riedel et al, 2013). Among these methods, the THz streak camera (Itatani et al, 2002;Frü hling et al, 2009;Grguraš et al, 2012;Helml et al, 2014;Juranić et al, 2014b) is able to measure both the length and the arrival time of the photon pulses at wavelengths ranging from UV to hard X-ray.…”
Section: Introductionmentioning
confidence: 99%