2006
DOI: 10.1016/j.bios.2005.05.006
|View full text |Cite
|
Sign up to set email alerts
|

Fiber-optic biosensor to assess circulating phagocyte activity by chemiluminescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 26 publications
(25 citation statements)
references
References 26 publications
0
25
0
Order By: Relevance
“…OZ was prepared fresh just before each experiment. KRP was composed of 119 mmol/L NaCl, 4.75 mmol/L KC1, 0.420 mmol/L CaCl2, 1.19 mmol/L, MgSO4·7H2O, 16.6 mmol/L sodium phosphate buffer, pH 7.4 and 5.56 mmol/L glucose (1).…”
Section: Preparation Of Stimulantsmentioning
confidence: 99%
See 2 more Smart Citations
“…OZ was prepared fresh just before each experiment. KRP was composed of 119 mmol/L NaCl, 4.75 mmol/L KC1, 0.420 mmol/L CaCl2, 1.19 mmol/L, MgSO4·7H2O, 16.6 mmol/L sodium phosphate buffer, pH 7.4 and 5.56 mmol/L glucose (1).…”
Section: Preparation Of Stimulantsmentioning
confidence: 99%
“…A novel luminometer for a fiber array-based biosensor was developed in our laboratory to monitor circulating phagocyte activity in whole blood (1). In order to better understand the mechanisms of reactive oxygen species (ROS) production by neutrophils, establishment of models based on a phagocyte cell line was needed.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In last two decades, significant progress has been made in the field of evanescence wave-induced fluorescence/chemiluminescencebased fiber-optic biosensors. [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15] Despite these advantages, the fiber-optic biosensors have been used, most of the time, only in detection of various kinds of biological analytes. 5,6,8,[11][12][13][14][15][16] Work on quantitative estimation of bioanalytes using fiber-optic sensors is very limited.…”
Section: Introductionmentioning
confidence: 99%
“…20 Most of the existing fluorescence/chemiluminescence systems use fluorimeter setup for detection of the fluorescence/ luminescence signal. 2,8,9,[11][12][13][14][15] We have used a charged-coupled device (CCD) based spectrometer to record the full spectral profile of the fluorescence signal. 6,10,16 The Least squares fitting method was used to extract a signal from recorded fluorescence spectral profile with the significantly enhanced signalto-background ratio.…”
Section: Introductionmentioning
confidence: 99%