Abstract:A fibre optic sensor was developed for in-situ pressure measurement based on the principle of differential pressure in liquids. This sensor system is very simple and consists of fibre Bragg grating (FBG) done on a fibre with core diameter of 9 µm. A calibration study was carried out with a water column and the pressure sensitivity was found to be 1.636 × 10 MPa -1 . The results show that response of FBG to the rise of water level is linear and agrees well with the theoretical results. The reliability of the se… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.