2020
DOI: 10.1016/j.tust.2020.103302
|View full text |Cite
|
Sign up to set email alerts
|

Fibre reinforced sprayed concrete for ground support

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(4 citation statements)
references
References 50 publications
0
3
0
1
Order By: Relevance
“…Hooked steel fibers can also be used in this inserting technique. Eventually, the 3DCP-SIT fabricates a printed fiber-reinforced concrete structure; the cast steel-fiber reinforced concrete attracted much research attention in past decades and was applied widely in construction [55], including tunneling [56].…”
Section: The 3dcp-sit Techniquementioning
confidence: 99%
“…Hooked steel fibers can also be used in this inserting technique. Eventually, the 3DCP-SIT fabricates a printed fiber-reinforced concrete structure; the cast steel-fiber reinforced concrete attracted much research attention in past decades and was applied widely in construction [55], including tunneling [56].…”
Section: The 3dcp-sit Techniquementioning
confidence: 99%
“…Untuk rekomendasi penyangga pada terowongan dapat dilihat pada Gambar 9 berikut ini Gambar 9. Rekomendasi penyangga terowongan berdasarkan (Q-System) Rekomendasi penyangga terowongan berdasarkan metode klasifikasi massa batuan (Q-System) adalah fibre reinforced sprayed concrete and bolting (Bernard & Thomas, 2020), yaitu Shotcrete dengan ketebalan 70 mm dengan spasi pemasangan Rockbolt ditambah Shotcrete 2,05 m, spasi pemasangan Rockbolt tanpa Shotcrete 1,5 m, dan panjang Rockbolt 4 m.…”
Section: Faktor Keamananunclassified
“…This is justified by the fact that MSFs are not sensitive to corrosion and its use has less CO 2 -eq associated respect to other steel-based reinforcement (both for production and considering the type of cements that can be used). It must be emphasized that MSFRC has already been satisfactorily used in precast concrete tunnels linings, [8][9][10][11][12][13][14][15] temporary and permanent sprayed concrete linings, 16 slabs-on ground, 17 precast panels for facades, 18 sewerage precast concrete pipes 19-22 [x], prestressed concrete elements subjected to flexure and shear as a replacement of stirrups, 23 and elevated flat slabs. 24,25 As per practical implementation of MSRFC in walls, however, there are reasonable technical and scientific questions due to the lack of experience that shall be provided with justifications and answers.…”
Section: Introductionmentioning