2008
DOI: 10.1016/j.chroma.2008.09.085
|View full text |Cite
|
Sign up to set email alerts
|

Flash column chromatograms estimated from thin-layer chromatography data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
36
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(37 citation statements)
references
References 12 publications
1
36
0
Order By: Relevance
“…Perylene red (generously gifted by BASF, Lumogen Red 305) was first used as received with a purity of only 90% (checked by spectroscopic and chromatographic methods). The dye purity was improved up to 99% by means of flash column chromatography [30] based on silica with hexane/ethyl acetate (95:5 v/v) as eluent, to remove the N-methyl-2-pyrrolidone, identified by 1 H NMR spectroscopy as the principal impurity. Solvents for laser studies were of spectroscopic grade (Merck, Aldrich, or Sigma) and were used without purification.…”
Section: Methodsmentioning
confidence: 99%
“…Perylene red (generously gifted by BASF, Lumogen Red 305) was first used as received with a purity of only 90% (checked by spectroscopic and chromatographic methods). The dye purity was improved up to 99% by means of flash column chromatography [30] based on silica with hexane/ethyl acetate (95:5 v/v) as eluent, to remove the N-methyl-2-pyrrolidone, identified by 1 H NMR spectroscopy as the principal impurity. Solvents for laser studies were of spectroscopic grade (Merck, Aldrich, or Sigma) and were used without purification.…”
Section: Methodsmentioning
confidence: 99%
“…[12] There is a variety of commercial flash chromatography instruments on the market, equipped with solvent pumps, manually packed columns or prepacked cartridges, detectors connected with microcomputers, and automatic fraction collectors. [12,13] Flash chromatography can endure relatively high flow rate with low pressure, offering good separation in a short time at a proper chromatographic condition. [14] In this paper, we reported a method for preparative isolation of tetrandrine and fangchinoline using reversed-phase flash chromatography.…”
Section: Radixmentioning
confidence: 99%
“…Evaporation of water by rotary evaporator was done to dryness of the samples. Weight of dried 20 urine samples was thus obtained (5.7 gm) and preserved for column chromatography [19][20][21][22] .…”
Section: Isolation and Seperation Of Cisplatin And Its Metabolites Frmentioning
confidence: 99%