Flexible Booster Chlorination: Design and Operation for Water Distribution Systems under Uncertainty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 29 publications
0
7
0
Order By: Relevance
“…Our simulation considers three sources of uncertainty (Basupi & Nono, 2019; Rico‐Ramirez et al., 2007) for multiperiod simulation. In this case, unknown disturbance can be simulated by hijacking or changing the concentrations at specific nodes or links suddenly.…”
Section: Case Studiesmentioning
confidence: 99%
“…Our simulation considers three sources of uncertainty (Basupi & Nono, 2019; Rico‐Ramirez et al., 2007) for multiperiod simulation. In this case, unknown disturbance can be simulated by hijacking or changing the concentrations at specific nodes or links suddenly.…”
Section: Case Studiesmentioning
confidence: 99%
“…The blue boxes showcase quantities that are given ahead of time while the red boxes are real-time, actual quantities that are not furnished for the control algorithm, considering that perfect parameters for the MPC controller is unrealistic. Our approach considers three sources of uncertainty [40], [41] for extended period simulation: (i) unknown disturbance (i.e., the chlorine concentration drops suddenly and unexpectedly due to the reaction with unknown intrusive chemicals-sodium arsenite or contamination events happen), (ii) demand uncertainty, and (iii) parameter uncertainty (i.e., estimated decay coefficients of chlorine in pipes and tanks k P and k TK is not accurate). The details and test results are in Section VI.…”
Section: Real-time Implementationmentioning
confidence: 99%
“…Our simulation considers three sources of uncertainty [40], [41] for multi-period simulation. In this case, unknown disturbance can be simulated by hijacking or changing the concentrations at specific nodes or links suddenly.…”
Section: A Three-node Networkmentioning
confidence: 99%
“…Locating chlorine boosters has been demonstrated using EPANET water-quality simulation (Abokifa et al 2019;Ayvaz and Kentel 2015;Basupi and Nono 2019;Seth et al 2017;Vrachimis et al 2021). Among these studies, Seth et al (2017) and Vrachimis et al (2021) focused on security concerns and emergency response in addition to secondary chlorine boosters to manage contamination detection issues.…”
Section: Introductionmentioning
confidence: 99%
“…Among these studies, Seth et al (2017) and Vrachimis et al (2021) focused on security concerns and emergency response in addition to secondary chlorine boosters to manage contamination detection issues. Basupi and Nono (2019) accounted for hydraulic uncertainties for the placement of chlorine boosters. Abokifa et al (2019) highlighted the limitation of the EPANET model especially for water-quality analysis of dead-end pipes and used an advectiondispersion-reaction transport model to solve the chlorine booster location problem.…”
Section: Introductionmentioning
confidence: 99%